Akron Recycle Energy Plant
- Combustion
- Retired
- 10 · 100 · 1,000 MW
Map
- Combustion
- Retired
Akron Recycle Energy Plant: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Akron Recycle Energy Plant
Power plant · Gas, steam turbine
Key facts
Power plant · Gas, steam turbine Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1979
- Net generation, 2007
- 0 MWh
- Location
- Summit County, Ohio
- Operated by
- Akron Energy Systems LLC
Operations
- Net generation, 2007
- 0
MWh - Fuel burned, 2007
- 1,009,664
MMBtu - Capacity factor, 2007
- Not stated
- Heat rate, 2007
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2007 | 0 | 1,009,664 | — | — |
| 2005 | 45 | 120,939 | 0.1% | — |
| 2004 (11 of 12 months) | 31 | 1,034,964 | — | — |
| 2003 | 0 | 932,955 | — | — |
| 2002 | 1,644 | 1,096,002 | 4.7% | — |
| 2001 | 309 | 400,476 | 0.9% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.