- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Camden South Carolina: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Camden South Carolina
Power plant · Gas, steam turbine
Output
- Gas
- Coal
- Oil
Details
Who’s behind it
- Owner
- Koch Industries Inc
Interested in this project?
- Technology
- Gas, steam turbine source: “Natural Gas Steam Turbine”
- Age
- 33 years since 1993
All 5 attributes from EIA-860M Preliminary Monthly Electric Generator Inventory
| Attribute | Value |
|---|---|
| EPA greenhouse gas reporting (GHGRP) |
|
| Eia status |
|
| Fuel burned (MMBtu), 2025 | 613,119 |
| Net generation (MWh), 2025 | 0 |
| Balancing authority code | CPLE |
Data notes (2)
- Capacity factor, 2025 not shown: net generation 0.0 MWh is not positive (the plant consumed at least as much as it produced over the year)
- Heat rate (Btu/kWh), 2025 not shown: fuel burned but net generation is not positive
Retirement
- Capacity retired
- 11 MW
- Generators retired
- 2
- Capacity still in service
- 19 MW
| Generator | Technology | Nameplate | State | Date |
|---|---|---|---|---|
| GEN1 | Natural Gas Steam Turbine | 5.5 MW | Retired | November 2019 |
| GEN2 | Natural Gas Steam Turbine | 5.5 MW | Retired | November 2019 |
Grid
EIA-860 2025Grid fieldsAs the plant reported them to EIA-860 for 2025 (Schedule 2).- Grid voltage at the plant
- 115 kV
- Transmission or distribution system owner
- Dominion Energy South Carolina, Inc
- Balancing authority
- Duke Energy Progress East
- NERC region
- SERC
Transmission lines within 15 mi (3)
Can the connection be reused?
A plant that retires usually leaves its substation, transmission connection and interconnection agreement behind, and those may be reusable by a new project at the same site. FERC Order No. 845 lets an interconnection customer use surplus interconnection service at an existing site, and some transmission providers' tariffs let a replacement resource take over a retiring unit's interconnection service, usually within a set time after the retirement. Whether any such right still exists here, who holds it and on what terms depends on the owner, the transmission provider and timing; this page does not establish any of that.
Ownership
2 companies2| Company | Role | Share | As of | Source |
|---|---|---|---|---|
| KOCH INDUSTRIES INC | Owner | 100.0% | Dec 31, 2023 | EPA GHGRP |
| Invista | Operator | EIA-860M |
Timeline
- Stated Units GEN1, GEN2 scheduled to retire, 11 MW · EIA-860M
- In service · EIA-860M
Sources
5 sourcesSources EIA-860M · LBNL · EIA · EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT) · EIA-860M Preliminary Monthly Electric Generator Inventory
Sources
- EIA-860M
- LBNLYin, Nait Belaid & Heleno (2026), Lawrence Berkeley National Laboratory, OEDI, CC BY 4.0: A Harmonized Geospatial Dataset of U.S. Transmission Lines: Linking FERC Form 1 and HIFLD, 1994-2024. Modified by Inframation: HIFLD-side fields only, names re-cased, coordinates rounded.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)
- EPA Greenhouse Gas Reporting Program — facility register with parent-company shares (Envirofacts pub_dim_facility; FLIGHT)
- EIA-860M Preliminary Monthly Electric Generator Inventory