Clearwater Paper Corporation - Augusta
- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Clearwater Paper Corporation - Augusta: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Clearwater Paper Corporation - Augusta
Power plant · Biomass
Key facts
Power plant · Biomassran 49% of 2024 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1960
- Net generation, 2024
- 366,954 MWh
- Grid
- 14 kV to Georgia Power Co (SOCO)
- Location
- Richmond County, Georgia
- Operated by
- Clearwater Paper Corporation - Augusta
Operations
- Net generation, 2024
- 366,954
MWh - Fuel burned, 2024
- 16,318,665
MMBtu - Capacity factor, 2024
- 49.3
% - Heat rate, 2024
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2024 | 366,954 | 16,318,665 | 49.3% | — |
| 2023 | 382,715 | 17,110,266 | 51.6% | — |
| 2022 | 393,866 | 18,186,784 | 53.1% | — |
| 2021 | 406,770 | 17,664,382 | 54.8% | — |
| 2020 | 388,873 | 17,749,690 | 52.3% | — |
| 2019 | 367,786 | 17,582,436 | 49.6% | — |
| 2018 | 373,124 | 16,334,531 | 50.3% | — |
| 2017 | 377,832 | 16,394,231 | 50.9% | — |
| 2016 | 377,910 | 15,280,570 | 50.8% | — |
| 2015 | 411,090 | 15,293,583 | 55.4% | — |
| 2014 | 408,454 | 14,630,115 | 55.0% | — |
| 2013 | 425,375 | 13,010,811 | 57.3% | — |
| 2012 | 445,570 | 17,542,476 | 59.9% | — |
| 2011 | 452,686 | 18,560,457 | 61.0% | — |
| 2010 | 437,616 | 18,961,007 | 59.0% | — |
| 2009 | 404,061 | 18,263,211 | 54.5% | — |
| 2008 | 447,254 | 21,301,809 | 60.1% | — |
| 2007 | 452,449 | 23,375,198 | 61.0% | — |
| 2006 | 465,106 | 25,016,721 | 62.7% | — |
| 2005 | 465,539 | 25,008,372 | 62.7% | — |
| 2004 | 450,821 | 23,396,939 | 60.6% | — |
| 2003 (10 of 12 months) | 417,097 | 19,103,283 | — | — |
| 2002 | 527,548 | 23,937,860 | 71.1% | — |
| 2001 | 476,160 | 24,189,678 | 64.2% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)