Columbia Energy Center (SC)
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 52% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2004
- Net generation, 2025
- 3,041,679 MWh
- Grid
- 230 kV, 115 kV to Dominion Energy South Carolina (SCEG)
- Location
- Calhoun County, South Carolina
- Operated by
- Dominion Energy South Carolina, Inc
Operations
- Net generation, 2025
- 3,041,679
MWh - Fuel burned, 2025
- 21,616,377
MMBtu - Capacity factor, 2025
- 51.9
% - Heat rate, 2025
- 7,107
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 1,906,352 | 13,905,835 | — | 7,294 |
| 2025 | 3,041,679 | 21,616,377 | 51.9% | 7,107 |
| 2024 | 3,259,026 | 23,284,394 | 55.5% | 7,145 |
| 2023 | 2,465,905 | 17,684,235 | 42.1% | 7,172 |
| 2022 | 2,711,313 | 19,616,543 | 46.3% | 7,235 |
| 2021 (11 of 12 months) | 2,519,808 | 18,265,359 | — | 7,249 |
| 2020 | 2,884,729 | 20,693,080 | 49.1% | 7,173 |
| 2019 | 3,251,100 | 23,507,091 | 55.5% | 7,230 |
| 2018 | 1,915,337 | 15,967,626 | 32.7% | 8,337 |
| 2017 | 1,676,278 | 12,427,777 | 28.6% | 7,414 |
| 2016 | 1,296,641 | 9,554,754 | 22.1% | 7,369 |
| 2015 | 750,159 | 5,712,617 | 12.8% | 7,615 |
| 2014 | 578,783 | 5,015,884 | 9.9% | 8,666 |
| 2013 | 701,952 | 5,802,971 | 12.0% | 8,267 |
| 2012 | 51,407 | 423,195 | 0.9% | 8,232 |
| 2011 | 151,214 | 1,267,747 | 2.6% | 8,384 |
| 2010 | 192,682 | 1,489,515 | 3.3% | 7,730 |
| 2009 | 44,188 | 350,334 | 0.8% | 7,928 |
| 2008 | 357,068 | 2,716,540 | 6.1% | 7,608 |
| 2007 | 393,888 | 3,434,594 | 6.7% | 8,720 |
| 2006 | 391,128 | 3,372,874 | 6.7% | 8,623 |
| 2005 | 387,473 | 3,559,181 | 6.6% | 9,186 |
| 2004 | 579,296 | 4,768,923 | 9.9% | 8,232 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)