Forks of Butte Hydro Project
- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
Forks of Butte Hydro Project: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Forks of Butte Hydro Project
Power plant · Hydro
Key facts
Power plant · Hydroran 46% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1992
- Net generation, 2025
- 58,151 MWh
- Grid
- 60 kV to Pacific Gas & Electric Co (CISO)
- Location
- Butte County, California
- Operated by
- Hypower Energy, LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 58,151
MWh - Fuel burned, 2025
- 198,410
MMBtu - Capacity factor, 2025
- 45.8
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 58,151 | 198,410 | 45.8% | — |
| 2024 | 65,935 | 224,969 | 51.8% | — |
| 2023 | 41,945 | 143,116 | 33.0% | — |
| 2022 | 9,863 | 33,652 | 7.8% | — |
| 2021 | 13,795 | 122,002 | 10.9% | — |
| 2020 | 14,940 | 130,978 | 11.7% | — |
| 2019 | 53,300 | 474,637 | 42.0% | — |
| 2018 | 29,769 | 271,018 | 23.4% | — |
| 2017 | 61,154 | 563,411 | 48.1% | — |
| 2016 | 51,348 | 474,045 | 40.3% | — |
| 2015 | 16,322 | 152,105 | 12.8% | — |
| 2014 | 21,597 | 205,386 | 17.0% | — |
| 2013 | 25,613 | 244,373 | 20.2% | — |
| 2012 | 32,245 | 306,843 | 25.3% | — |
| 2011 | 56,324 | 547,246 | 44.3% | — |
| 2010 | 63,549 | 619,982 | 50.0% | — |
| 2009 | 31,447 | 306,925 | 24.8% | — |
| 2008 | 27,689 | 272,847 | 21.7% | — |
| 2007 | 19,663 | 194,349 | 15.5% | — |
| 2006 | 60,514 | 600,238 | 47.6% | — |
| 2005 | 52,924 | 529,187 | 41.7% | — |
| 2004 | 39,275 | 393,614 | 30.8% | — |
| 2003 | 57,888 | 592,831 | 45.6% | — |
| 2002 | 35,672 | 362,891 | 28.1% | — |
| 2001 | 31,538 | 325,882 | 24.8% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.