- Bioenergy
- Retired
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Retired
Hopkinton Energy: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Hopkinton Energy
Power plant · Biomass
Key facts
Power plant · Biomassran 18% of 2002 Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1984
- Net generation, 2002
- 19,609 MWh
- Location
- Merrimack County, New Hampshire
- Operated by
- Regenesis CorporationSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2002
- 19,609
MWh - Fuel burned, 2002
- 550,492
MMBtu - Capacity factor, 2002
- 17.8
% - Heat rate, 2002
- 28,073
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2002 | 19,609 | 550,492 | 17.8% | 28,073 |
| 2001 | 79,606 | 1,087,448 | 72.1% | 13,660 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.