- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Hutchinson Plant #1: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Hutchinson Plant #1
Power plant · Gas, reciprocating engine
Key facts
Power plant · Gas, reciprocating engineran 17% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2013
- Net generation, 2025
- 41,896 MWh
- Grid
- 14 kV to Hutchinson Utilities Comm (MISO)
- Location
- McLeod County, Minnesota
- Operated by
- Hutchinson Utilities CommSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 41,896
MWh - Fuel burned, 2025
- 358,825
MMBtu - Capacity factor, 2025
- 16.8
% - Heat rate, 2025
- 8,565
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 41,896 | 358,825 | 16.8% | 8,565 |
| 2024 | 35,674 | 306,215 | 14.3% | 8,584 |
| 2023 | 30,744 | 262,912 | 12.4% | 8,552 |
| 2022 | 27,642 | 237,934 | 11.1% | 8,608 |
| 2021 | 34,364 | 294,845 | 13.8% | 8,580 |
| 2020 | 10,018 | 86,221 | 4.0% | 8,607 |
| 2019 | 7,400 | 66,814 | 3.0% | 9,029 |
| 2018 | 11,436 | 113,431 | 4.6% | 9,919 |
| 2017 | 8,513 | 80,490 | 3.4% | 9,455 |
| 2016 | 15,943 | 166,006 | 6.4% | 10,412 |
| 2015 | 12,855 | 132,681 | 5.2% | 10,321 |
| 2014 | 15,483 | 140,770 | 6.2% | 9,092 |
| 2013 | 19,390 | 186,865 | 7.8% | 9,637 |
| 2012 | 6,138 | 62,064 | 2.5% | 10,111 |
| 2011 | 3,786 | 36,398 | 1.5% | 9,614 |
| 2010 | 4,351 | 44,626 | 1.8% | 10,256 |
| 2009 | 4,128 | 37,147 | 1.7% | 8,999 |
| 2008 | 3,961 | 35,088 | 1.6% | 8,858 |
| 2007 | 3,890 | 37,958 | 1.6% | 9,758 |
| 2006 | 587 | 6,492 | 0.2% | 11,060 |
| 2005 | 1,453 | 13,526 | 0.6% | 9,309 |
| 2004 | 460 | 4,703 | 0.2% | 10,224 |
| 2003 (11 of 12 months) | 971 | 10,062 | — | 10,362 |
| 2002 | 2,236 | 25,730 | 0.9% | 11,507 |
| 2001 | 5,501 | 68,746 | 2.2% | 12,497 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.