- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
International Paper Pensacola: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
International Paper Pensacola
Power plant · Biomass
Key facts
Power plant · Biomassran 48% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1981
- Net generation, 2025
- 348,464 MWh
- Grid
- 14 kV to Florida Power & Light Co (SOCO)
- Location
- Escambia County, Florida
- Operated by
- International Paper Co-PensacolaSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 348,464
MWh - Fuel burned, 2025
- 12,511,696
MMBtu - Capacity factor, 2025
- 48.0
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 348,464 | 12,511,696 | 48.0% | — |
| 2024 | 343,941 | 14,522,974 | 47.3% | — |
| 2023 | 336,210 | 14,189,669 | 46.4% | — |
| 2022 | 377,799 | 15,641,890 | 52.1% | — |
| 2021 | 446,698 | 18,336,465 | 61.6% | — |
| 2020 | 457,246 | 18,996,349 | 62.9% | — |
| 2019 | 449,346 | 18,944,784 | 62.0% | — |
| 2018 | 471,992 | 14,497,988 | 65.1% | — |
| 2017 | 421,049 | 16,874,360 | 58.1% | — |
| 2016 | 490,116 | 18,267,571 | 67.4% | — |
| 2015 | 514,106 | 18,299,692 | 70.9% | — |
| 2014 | 404,027 | 16,362,702 | 55.7% | — |
| 2013 | 504,074 | 18,319,077 | 69.5% | — |
| 2012 | 503,740 | 17,826,549 | 69.3% | — |
| 2011 | 484,330 | 18,332,802 | 66.8% | — |
| 2010 | 511,086 | 18,079,880 | 70.5% | — |
| 2009 | 441,695 | 17,640,585 | 60.9% | — |
| 2008 | 399,111 | 16,826,889 | 54.9% | — |
| 2007 | 331,002 | 14,804,224 | 45.6% | — |
| 2006 | 360,279 | 17,219,339 | 49.7% | — |
| 2005 | 374,014 | 17,345,114 | 51.6% | — |
| 2004 (11 of 12 months) | 372,956 | 17,325,655 | — | — |
| 2003 | 463,167 | 19,758,653 | 63.9% | — |
| 2002 | 153,947 | 8,839,013 | 21.2% | — |
| 2001 | 394,269 | 20,696,322 | 54.4% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)