International Paper Riverdale Mill
- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
International Paper Riverdale Mill: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
International Paper Riverdale Mill
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 60% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1967
- Net generation, 2025
- 552,158 MWh
- Grid
- 115 kV to Alabama Power Co (SOCO)
- Location
- Dallas County, Alabama
- Operated by
- International Paper Co-Riverdl
Operations
- Net generation, 2025
- 552,158
MWh - Fuel burned, 2025
- 19,548,931
MMBtu - Capacity factor, 2025
- 60.5
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 552,158 | 19,548,931 | 60.5% | — |
| 2024 | 562,248 | 19,211,079 | 61.4% | — |
| 2023 | 462,678 | 19,108,973 | 50.7% | — |
| 2022 | 400,141 | 15,437,604 | 43.8% | — |
| 2021 | 620,019 | 16,349,354 | 67.9% | 26,369 |
| 2020 | 353,392 | 8,815,740 | 38.6% | 24,946 |
| 2019 | 601,672 | 15,268,757 | 65.9% | 25,377 |
| 2018 | 605,207 | 14,212,435 | 66.3% | 23,484 |
| 2017 | 587,101 | 14,268,813 | 64.3% | 24,304 |
| 2016 | 576,969 | 15,651,349 | 63.0% | 27,127 |
| 2015 | 553,443 | 15,129,988 | 60.6% | 27,338 |
| 2014 | 550,417 | 15,304,796 | 60.3% | 27,806 |
| 2013 | 568,140 | 15,309,566 | 62.2% | 26,947 |
| 2012 | 612,371 | 15,943,388 | 66.9% | 26,036 |
| 2011 | 551,527 | 17,141,486 | 60.4% | — |
| 2010 | 445,778 | 15,854,703 | 48.8% | — |
| 2009 | 322,727 | 12,363,284 | 35.4% | — |
| 2008 | 363,294 | 14,840,072 | 39.7% | — |
| 2007 | 367,048 | 16,764,818 | 40.2% | — |
| 2006 | 372,219 | 22,297,904 | 40.8% | — |
| 2005 | 469,446 | 17,455,370 | 51.4% | — |
| 2004 | 569,009 | 19,356,109 | 62.2% | — |
| 2003 (6 of 12 months) | 315,766 | 9,851,088 | — | — |
| 2002 | 651,918 | 19,689,301 | 71.4% | — |
| 2001 | 679,031 | 22,611,750 | 74.4% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)