John B Rich Memorial Power Station
- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
John B Rich Memorial Power Station: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
John B Rich Memorial Power Station
Power plant · Coal
Key facts
Power plant · Coalran 83% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1988
- Net generation, 2025
- 641,892 MWh
- Grid
- 69 kV to PPL Electric Utilities Corp (PJM)
- Location
- Schuylkill County, Pennsylvania
- Operated by
- Gilberton Power Co
Operations
- Net generation, 2025
- 641,892
MWh - Fuel burned, 2025
- 9,100,733
MMBtu - Capacity factor, 2025
- 82.9
% - Heat rate, 2025
- 14,178
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 641,892 | 9,100,733 | 82.9% | 14,178 |
| 2024 | 616,874 | 8,641,802 | 79.4% | 14,009 |
| 2023 | 624,055 | 8,995,757 | 80.6% | 14,415 |
| 2022 | 637,542 | 9,471,970 | 82.3% | 14,857 |
| 2021 | 583,476 | 8,884,856 | 75.3% | 15,228 |
| 2020 | 634,279 | 9,154,342 | 81.7% | 14,433 |
| 2019 | 624,307 | 8,531,769 | 80.6% | 13,666 |
| 2018 | 612,078 | 8,729,220 | 79.0% | 14,262 |
| 2017 | 634,555 | 8,105,310 | 81.9% | 12,773 |
| 2016 | 631,279 | 8,407,375 | 81.3% | 13,318 |
| 2015 | 631,819 | 8,712,007 | 81.6% | 13,789 |
| 2014 | 621,950 | 8,597,421 | 80.3% | 13,823 |
| 2013 | 654,377 | 8,318,883 | 84.5% | 12,713 |
| 2012 | 419,956 | 6,167,385 | 54.1% | 14,686 |
| 2011 | 641,442 | 8,904,899 | 82.8% | 13,883 |
| 2010 | 585,516 | 8,364,898 | 75.6% | 14,286 |
| 2009 | 558,066 | 7,689,883 | 72.1% | 13,780 |
| 2008 | 608,505 | 8,277,324 | 78.4% | 13,603 |
| 2007 | 644,137 | 9,205,876 | 83.2% | 14,292 |
| 2006 | 711,737 | 9,489,328 | 91.9% | 13,333 |
| 2005 | 713,907 | 9,269,452 | 92.2% | 12,984 |
| 2004 | 722,805 | 9,067,551 | 93.1% | 12,545 |
| 2003 | 669,544 | 9,213,624 | 86.5% | 13,761 |
| 2002 | 508,953 | 6,150,696 | 65.7% | 12,085 |
| 2001 | 724,765 | 8,433,982 | 93.6% | 11,637 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)