- Wind & solar
- Retired
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Retired
Little Pringle II Wind Farm: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Little Pringle II Wind Farm
Power plant · Wind
Key facts
Power plant · Wind Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2010
- Net generation, 2024
- 0 MWh
- Grid
- 34 kV to Southwestern Public Service Co (SWPP)
- Location
- Hutchinson County, Texas
- Operated by
- Everpoint Services IncSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2024
- 0
MWh - Fuel burned, 2024
- 0
MMBtu - Capacity factor, 2024
- Not stated
- Heat rate, 2024
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2024 | 0 | 0 | — | — |
| 2023 | 0 | 0 | — | — |
| 2020 | 0 | 0 | — | — |
| 2019 | 0 | 0 | — | — |
| 2018 | 0 | 0 | — | — |
| 2017 | 9,720 | 89,551 | 11.1% | — |
| 2016 | 15,563 | 143,679 | 17.7% | — |
| 2015 | 18,989 | 176,959 | 21.7% | — |
| 2014 | 23,549 | 223,951 | 26.9% | — |
| 2013 | 26,520 | 253,028 | 30.3% | — |
| 2012 | 33,218 | 316,101 | 37.8% | — |
| 2011 | 28,747 | 279,306 | 32.8% | — |
| 2010 | 3,088 | 30,126 | 3.5% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.