- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Middletown Coke Company, LLC: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Middletown Coke Company, LLC
Power plant · Gas, other
Key facts
Power plant · Gas, otherran 51% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2011
- Net generation, 2025
- 301,650 MWh
- Grid
- 69 kV to Duke Energy Ohio Inc (PJM)
- Location
- Butler County, Ohio
- Operated by
- Suncoke Energy IncSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 301,650
MWh - Fuel burned, 2025
- 6,923,954
MMBtu - Capacity factor, 2025
- 51.4
% - Heat rate, 2025
- 22,954
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 301,650 | 6,923,954 | 51.4% | 22,954 |
| 2024 | 349,524 | 6,802,976 | 59.4% | 19,464 |
| 2023 | 333,038 | 7,015,084 | 56.7% | 21,064 |
| 2022 | 353,002 | 6,813,129 | 60.1% | 19,300 |
| 2021 | 360,406 | 6,794,135 | 61.4% | 18,851 |
| 2020 | 320,184 | 6,074,560 | 54.4% | 18,972 |
| 2019 | 309,687 | 6,681,446 | 52.8% | 21,575 |
| 2018 | 350,176 | 6,791,576 | 59.7% | 19,395 |
| 2017 | 345,687 | 6,360,402 | 58.9% | 18,399 |
| 2016 | 369,239 | 6,629,667 | 62.7% | 17,955 |
| 2015 | 404,446 | 6,368,903 | 68.9% | 15,747 |
| 2014 | 384,387 | 6,569,661 | 65.5% | 17,091 |
| 2013 | 384,861 | 6,529,303 | 65.6% | 16,965 |
| 2012 | 384,308 | 8,459,373 | 65.3% | 22,012 |
| 2011 (1 of 12 months) | 18,137 | 2,433,158 | — | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)