Montfort Wind Energy Center
- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
Montfort Wind Energy Center: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Montfort Wind Energy Center
Power plant · Wind
Key facts
Power plant · Windran 21% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2002
- Net generation, 2025
- 54,606 MWh
- Grid
- 69 kV to American Transmission Co (MISO)
- Location
- Iowa County, Wisconsin
- Operated by
- Wisconsin Electric Power CoSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 54,606
MWh - Fuel burned, 2025
- 186,315
MMBtu - Capacity factor, 2025
- 20.8
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (9 of 12 months) | 34,380 | 117,303 | — | — |
| 2025 | 54,606 | 186,315 | 20.8% | — |
| 2024 | 58,197 | 198,567 | 22.1% | — |
| 2023 | 45,632 | 155,697 | 17.4% | — |
| 2022 | 64,230 | 219,152 | 24.4% | — |
| 2021 | 52,038 | 460,224 | 19.8% | — |
| 2020 | 52,709 | 462,100 | 20.0% | — |
| 2019 | 45,408 | 404,357 | 17.3% | — |
| 2018 | 39,872 | 362,996 | 15.2% | — |
| 2017 | 48,308 | 445,063 | 18.4% | — |
| 2016 | 46,660 | 430,766 | 17.7% | — |
| 2015 | 53,302 | 496,721 | 20.3% | — |
| 2014 | 58,949 | 560,603 | 22.4% | — |
| 2013 | 54,058 | 515,767 | 20.6% | — |
| 2012 | 56,406 | 536,758 | 21.4% | — |
| 2011 | 54,145 | 526,072 | 20.6% | — |
| 2010 | 52,599 | 513,154 | 20.0% | — |
| 2009 | 54,849 | 535,325 | 20.9% | — |
| 2008 | 58,677 | 578,203 | 22.3% | — |
| 2007 | 62,671 | 619,442 | 23.8% | — |
| 2006 | 62,442 | 619,363 | 23.8% | — |
| 2005 | 55,263 | 552,575 | 21.0% | — |
| 2004 | 60,186 | 603,184 | 22.8% | — |
| 2003 | 54,844 | 561,657 | 20.9% | — |
| 2002 | 60,747 | 617,979 | 23.1% | — |
| 2001 | 28,520 | 294,697 | 10.8% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)