Paxton Creek Cogeneration
Power plant · Gas, reciprocating engine
Key facts
Power plant · Gas, reciprocating engineran 2% of 2025 Standby- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1986
- Net generation, 2025
- 2,123 MWh
- Grid
- 69 kV, 12 kV to PPL Electric Utilities Corp (PJM)
- Location
- Dauphin County, Pennsylvania
- Operated by
- Energy Center Paxton LLC
Operations
- Net generation, 2025
- 2,123
MWh - Fuel burned, 2025
- 21,189
MMBtu - Capacity factor, 2025
- 1.9
% - Heat rate, 2025
- 9,981
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 2,123 | 21,189 | 1.9% | 9,981 |
| 2024 | 693 | 7,052 | 0.6% | 10,176 |
| 2023 | 414 | 4,177 | 0.4% | 10,089 |
| 2022 | 3,683 | 36,773 | 3.3% | 9,984 |
| 2021 | 5,010 | 49,737 | 4.5% | 9,928 |
| 2020 | 3,743 | 36,970 | 3.4% | 9,877 |
| 2019 | 388 | 3,839 | 0.4% | 9,894 |
| 2018 | 1,263 | 12,217 | 1.1% | 9,673 |
| 2017 | 881 | 8,729 | 0.8% | 9,908 |
| 2016 | 3,380 | 32,429 | 3.0% | 9,594 |
| 2015 | 3,290 | 31,885 | 3.0% | 9,692 |
| 2014 | 1,081 | 10,117 | 1.0% | 9,359 |
| 2013 | 2,354 | 22,703 | 2.1% | 9,644 |
| 2012 | 1,709 | 16,491 | 1.5% | 9,650 |
| 2011 | 3,039 | 30,047 | 2.8% | 9,887 |
| 2010 | 5,374 | 53,665 | 4.9% | 9,986 |
| 2009 | 2,185 | 21,346 | 2.0% | 9,769 |
| 2008 | 5,809 | 55,461 | 5.2% | 9,547 |
| 2007 | 4,593 | 44,119 | 4.2% | 9,606 |
| 2006 | 4,042 | 38,275 | 3.7% | 9,470 |
| 2005 | 6,305 | 216,718 | 5.7% | — |
| 2004 | 9,302 | 79,409 | 8.4% | 8,537 |
| 2003 | 4,659 | 46,238 | 4.2% | 9,924 |
| 2002 | 6,655 | 66,267 | 6.0% | 9,958 |
| 2001 | 7,047 | 64,733 | 6.4% | 9,186 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.