- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Settlers Hill Gas Recovery: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Settlers Hill Gas Recovery
Power plant · Biomass
Key facts
Power plant · Biomassran 42% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1988
- Net generation, 2025
- 22,229 MWh
- Grid
- 13 kV to City of Geneva- (IL) (PJM)
- Location
- Kane County, Illinois
- Operated by
- WM Illinois Renewable Energy LLC
Operations
- Net generation, 2025
- 22,229
MWh - Fuel burned, 2025
- 424,060
MMBtu - Capacity factor, 2025
- 42.3
% - Heat rate, 2025
- 19,077
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 22,229 | 424,060 | 42.3% | 19,077 |
| 2024 | 21,476 | 460,145 | 40.8% | 21,426 |
| 2023 | 24,873 | 488,210 | 47.3% | 19,628 |
| 2022 | 23,373 | 519,685 | 44.5% | 22,234 |
| 2021 | 27,797 | 578,938 | 52.9% | 20,827 |
| 2020 | 30,539 | 611,888 | 57.9% | 20,036 |
| 2019 | 32,950 | 644,480 | 62.7% | 19,559 |
| 2018 | 33,043 | 637,389 | 62.9% | 19,290 |
| 2017 | 34,840 | 565,958 | 66.3% | 16,244 |
| 2016 | 38,452 | 700,024 | 73.0% | 18,205 |
| 2015 | 40,640 | 721,529 | 77.3% | 17,754 |
| 2014 | 42,741 | 758,124 | 81.3% | 17,738 |
| 2013 | 43,533 | 774,515 | 82.8% | 17,791 |
| 2012 | 42,232 | 737,074 | 80.1% | 17,453 |
| 2011 | 42,030 | 750,023 | 80.0% | 17,845 |
| 2010 | 41,125 | 729,318 | 78.2% | 17,734 |
| 2009 | 42,952 | 761,715 | 81.7% | 17,734 |
| 2008 | 41,260 | 732,777 | 78.3% | 17,760 |
| 2007 | 41,642 | 744,217 | 79.2% | 17,872 |
| 2006 | 41,335 | 740,995 | 78.6% | 17,927 |
| 2005 | 39,880 | 731,141 | 75.9% | 18,334 |
| 2004 | 38,539 | 711,732 | 73.1% | 18,468 |
| 2003 | 39,648 | 727,131 | 75.4% | 18,340 |
| 2002 | 41,171 | 739,086 | 78.3% | 17,952 |
| 2001 | 41,097 | 668,907 | 78.2% | 16,276 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.