Sixth Street Gas Turbine
- Combustion
- Retired
- 10 · 100 · 1,000 MW
Map
- Combustion
- Retired
Sixth Street Gas Turbine: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Sixth Street Gas Turbine
Power plant · Oil
Key facts
Power plant · Oil Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1974
- Net generation, 2022
- -152 MWh
- Grid
- 138 kV to City of Holland (MISO)
- Location
- Ottawa County, Michigan
- Operated by
- City of Holland - (MI)SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2022
- -152
MWh - Fuel burned, 2022
- 251
MMBtu - Capacity factor, 2022
- Not stated
- Heat rate, 2022
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2023 (5 of 12 months) | -77 | 40 | — | — |
| 2022 | -152 | 251 | — | — |
| 2021 | -95 | 1,002 | — | — |
| 2020 | -99 | 758 | — | — |
| 2019 | -120 | 849 | — | — |
| 2018 | -125 | 626 | — | — |
| 2017 | -68 | 481 | — | — |
| 2016 | -133 | 566 | — | — |
| 2015 | -78 | 753 | — | — |
| 2014 | -101 | 713 | — | — |
| 2013 | -89 | 658 | — | — |
| 2012 | -112 | 140 | — | — |
| 2011 | 66 | 2,387 | 0.0% | — |
| 2010 | -39 | 3,199 | — | — |
| 2009 | -118 | 147 | — | — |
| 2008 | -140 | 141 | — | — |
| 2007 | 1 | 82 | 0.0% | — |
| 2006 | 0 | 174 | — | — |
| 2005 | 0 | 133 | — | — |
| 2004 | 0 | 0 | — | — |
| 2003 (11 of 12 months) | 0 | 0 | — | — |
| 2002 | 0 | 0 | — | — |
| 2001 | 309 | 4,408 | 0.1% | 14,265 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.