Spokane Waste to Energy
- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Spokane Waste to Energy: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Spokane Waste to Energy
Power plant · Waste to energy
Key facts
Power plant · Waste to energyran 59% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1991
- Net generation, 2025
- 134,535 MWh
- Grid
- 115 kV to Avista Corp (AVA)
- Location
- Spokane County, Washington
- Operated by
- City of Spokane - (WA)
Operations
- Net generation, 2025
- 134,535
MWh - Fuel burned, 2025
- 2,587,329
MMBtu - Capacity factor, 2025
- 59.1
% - Heat rate, 2025
- 19,232
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (9 of 12 months) | 98,616 | 1,874,387 | — | 19,007 |
| 2025 | 134,535 | 2,587,329 | 59.1% | 19,232 |
| 2024 | 132,379 | 2,623,600 | 58.0% | 19,819 |
| 2023 | 124,693 | 2,486,651 | 54.8% | 19,942 |
| 2022 | 106,279 | 2,445,740 | 46.7% | 23,012 |
| 2021 | 119,619 | 2,629,769 | 52.5% | 21,984 |
| 2020 | 125,280 | 2,572,504 | 54.9% | 20,534 |
| 2019 | 121,031 | 2,559,631 | 53.1% | 21,149 |
| 2018 | 123,285 | 2,565,688 | 54.1% | 20,811 |
| 2017 | 115,875 | 2,597,423 | 50.9% | 22,416 |
| 2016 | 122,486 | 2,646,603 | 53.6% | 21,607 |
| 2015 | 110,118 | 2,470,327 | 48.4% | 22,434 |
| 2014 | 132,721 | 2,701,511 | 58.3% | 20,355 |
| 2013 | 136,892 | 2,766,280 | 60.1% | 20,208 |
| 2012 | 140,298 | 2,837,142 | 61.4% | 20,222 |
| 2011 | 143,383 | 2,849,168 | 62.9% | 19,871 |
| 2010 | 141,498 | 2,888,562 | 62.1% | 20,414 |
| 2009 | 133,989 | 2,775,585 | 58.8% | 20,715 |
| 2008 | 128,131 | 2,615,893 | 56.1% | 20,416 |
| 2007 | 141,748 | 2,810,225 | 62.2% | 19,826 |
| 2006 | 141,330 | 2,862,957 | 62.1% | 20,257 |
| 2005 | 147,323 | 2,880,790 | 64.7% | 19,554 |
| 2004 | 148,587 | 2,893,416 | 65.1% | 19,473 |
| 2003 (11 of 12 months) | 119,731 | 2,233,810 | — | 18,657 |
| 2002 | 145,952 | 2,669,976 | 64.1% | 18,294 |
| 2001 | 138,686 | 2,593,518 | 60.9% | 18,701 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)