Winnebago County Landfill Gas
Power plant · Biomass
Key facts
Power plant · Biomassran 25% of 2025 Retiring- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2000
- Net generation, 2025
- 3,232 MWh
- Grid
- 25 kV to Wisconsin Public Service Corp (MISO)
- Location
- Winnebago County, Wisconsin
- Operated by
- Winnebago County - (WI)
Operations
- Net generation, 2025
- 3,232
MWh - Fuel burned, 2025
- 126,075
MMBtu - Capacity factor, 2025
- 24.6
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 3,232 | 126,075 | 24.6% | — |
| 2024 | 8,832 | 63,568 | 67.0% | 7,198 |
| 2023 | 11,417 | 120,818 | 86.9% | 10,582 |
| 2022 | 9,493 | 119,451 | 72.2% | 12,583 |
| 2021 | 14,800 | 180,702 | — | 12,210 |
| 2020 | 17,073 | 199,855 | — | 11,706 |
| 2019 | 18,725 | 210,353 | — | 11,234 |
| 2018 | 19,727 | 231,204 | — | 11,720 |
| 2017 | 24,405 | 278,404 | — | 11,408 |
| 2016 | 29,849 | 338,894 | — | 11,354 |
| 2015 | 33,046 | 372,769 | — | 11,280 |
| 2014 | 34,607 | 391,497 | — | 11,313 |
| 2013 | 36,342 | 382,378 | — | 10,522 |
| 2012 | 38,923 | 403,153 | — | 10,358 |
| 2011 | 36,078 | 359,260 | — | 9,958 |
| 2010 | 24,519 | 259,481 | — | 10,583 |
| 2009 | 23,058 | 241,020 | — | 10,453 |
| 2008 | 19,971 | 215,895 | — | 10,810 |
| 2007 | 19,448 | 192,086 | — | 9,877 |
| 2006 | 15,426 | 152,869 | — | 9,910 |
| 2005 | 13,783 | 133,775 | 104.9% | 9,706 |
| 2004 | 17,263 | 159,518 | — | 9,240 |
| 2003 | 17,834 | 159,303 | — | 8,932 |
| 2002 | 19,798 | 191,922 | — | 9,694 |
| 2001 | 18,149 | 177,517 | — | 9,781 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.