- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
AL Sandersville LLC: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
AL Sandersville LLC
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 5% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2002
- Net generation, 2025
- 326,170 MWh
- Grid
- 500 kV to Georgia Power Co (SOCO)
- Location
- Washington County, Georgia
- Operated by
- CAMS (Georgia) AL Sandersville
Operations
- Net generation, 2025
- 326,170
MWh - Fuel burned, 2025
- 4,113,752
MMBtu - Capacity factor, 2025
- 5.4
% - Heat rate, 2025
- 12,612
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 326,170 | 4,113,752 | 5.4% | 12,612 |
| 2024 | 154,316 | 1,872,081 | 2.5% | 12,132 |
| 2023 | 90,264 | 1,190,380 | 1.5% | 13,188 |
| 2022 | 285,386 | 1,930,290 | 4.7% | 6,764 |
| 2021 | 130,545 | 1,593,739 | 2.1% | 12,208 |
| 2020 | 35,483 | 451,390 | 0.6% | 12,721 |
| 2019 | 93,046 | 835,739 | 1.5% | 8,982 |
| 2018 | 73,109 | 840,031 | 1.2% | 11,490 |
| 2017 | 1,145 | 15,248 | 0.0% | 13,317 |
| 2016 | 6,974 | 85,470 | 0.1% | 12,256 |
| 2015 | 7,382 | 90,353 | 0.1% | 12,240 |
| 2014 | 9,041 | 111,255 | 0.1% | 12,306 |
| 2013 | 3,529 | 43,895 | 0.1% | 12,438 |
| 2012 | 33,050 | 404,487 | 0.5% | 12,239 |
| 2011 | 13,925 | 170,177 | 0.2% | 12,221 |
| 2010 | 48,655 | 594,698 | 0.8% | 12,223 |
| 2009 | 13,847 | 178,201 | 0.2% | 12,869 |
| 2008 | 14,364 | 179,374 | 0.2% | 12,488 |
| 2007 | 78,605 | 966,288 | 1.3% | 12,293 |
| 2006 | 26,191 | 308,438 | 0.4% | 11,776 |
| 2005 | 4,806 | 56,527 | 0.1% | 11,762 |
| 2004 | 6,042 | 82,402 | 0.1% | 13,638 |
| 2003 | 6,172 | 53,308 | 0.1% | 8,637 |
| 2002 (5 of 12 months) | 17,386 | 215,753 | — | 12,410 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)