Power plant · Biomass
Key facts
Power plant · Biomassran 74% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1989
- Net generation, 2025
- 38,769 MWh
- Grid
- 22 kV to Pacific Gas & Electric Co (CISO)
- Location
- Alameda County, California
- Operated by
- WM Renewable Energy LLC
Operations
- Net generation, 2025
- 38,769
MWh - Fuel burned, 2025
- 721,517
MMBtu - Capacity factor, 2025
- 73.8
% - Heat rate, 2025
- 18,611
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 38,769 | 721,517 | 73.8% | 18,611 |
| 2024 | 38,937 | 717,966 | 73.9% | 18,439 |
| 2023 | 39,367 | 725,865 | 74.9% | 18,438 |
| 2022 | 32,346 | 637,672 | 61.5% | 19,714 |
| 2021 | 34,440 | 665,898 | 65.5% | 19,335 |
| 2020 | 38,079 | 721,210 | 72.2% | 18,940 |
| 2019 | 39,752 | 726,722 | 75.6% | 18,281 |
| 2018 | 40,578 | 732,497 | 77.2% | 18,052 |
| 2017 | 41,863 | 761,714 | 79.7% | 18,195 |
| 2016 | 45,492 | 806,911 | 86.3% | 17,737 |
| 2015 | 48,598 | 897,923 | 92.5% | 18,476 |
| 2014 | 52,075 | 760,561 | 99.1% | 14,605 |
| 2013 | 52,075 | 896,770 | 99.1% | 17,221 |
| 2012 | 53,761 | 918,335 | 102.0% | 17,082 |
| 2011 | 55,121 | 942,807 | 104.9% | 17,104 |
| 2010 | 50,141 | 879,237 | 95.4% | 17,535 |
| 2009 | 43,646 | 775,030 | 83.0% | 17,757 |
| 2008 | 48,149 | 811,524 | 91.4% | 16,854 |
| 2007 | 48,729 | 877,955 | 92.7% | 18,017 |
| 2006 | 53,655 | 904,262 | 102.1% | 16,853 |
| 2005 | 49,569 | 708,146 | 94.3% | 14,286 |
| 2004 | 41,466 | 746,283 | 78.7% | 17,998 |
| 2003 | 39,317 | 737,119 | 74.8% | 18,748 |
| 2002 | 40,727 | 743,718 | 77.5% | 18,261 |
| 2001 | 38,814 | 1,085,311 | 73.9% | 27,962 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.