- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Anclote: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Anclote
Power plant · Gas, steam turbine
Key facts
Power plant · Gas, steam turbineran 21% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1974
- Net generation, 2025
- 2,015,598 MWh
- Location
- Pasco County, Florida
- Operated by
- Duke Energy Florida, LLC
Operations
- Net generation, 2025
- 2,015,598
MWh - Fuel burned, 2025
- 24,106,879
MMBtu - Capacity factor, 2025
- 20.7
% - Heat rate, 2025
- 11,960
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 1,600,873 | 18,614,967 | — | 11,628 |
| 2025 | 2,015,598 | 24,106,879 | 20.7% | 11,960 |
| 2024 | 1,635,965 | 19,518,986 | 16.7% | 11,931 |
| 2023 | 1,737,284 | 21,642,731 | 17.8% | 12,458 |
| 2022 | 2,248,564 | 25,652,245 | 23.1% | 11,408 |
| 2021 | 2,112,063 | 23,852,851 | 21.7% | 11,294 |
| 2020 | 2,243,889 | 26,297,975 | 23.0% | 11,720 |
| 2019 | 2,278,498 | 25,640,356 | 23.4% | 11,253 |
| 2018 | 2,714,482 | 29,898,900 | 27.9% | 11,015 |
| 2017 | 2,869,608 | 31,381,779 | 29.4% | 10,936 |
| 2016 | 3,498,181 | 37,690,662 | 35.8% | 10,774 |
| 2015 (11 of 12 months) | 2,723,353 | 30,412,034 | — | 11,167 |
| 2014 | 2,433,908 | 27,251,759 | 25.0% | 11,197 |
| 2013 | 1,556,246 | 18,508,572 | 16.0% | 11,893 |
| 2012 | 1,707,239 | 21,190,709 | 17.5% | 12,412 |
| 2011 | 1,613,800 | 20,658,170 | 16.6% | 12,801 |
| 2010 | 1,887,407 | 23,241,293 | 19.4% | 12,314 |
| 2009 | 1,586,222 | 19,494,080 | 16.3% | 12,290 |
| 2008 | 2,457,705 | 26,907,600 | 25.1% | 10,948 |
| 2007 | 3,289,292 | 34,096,322 | 33.8% | 10,366 |
| 2006 | 2,940,530 | 30,232,353 | 30.2% | 10,281 |
| 2005 | 4,302,160 | 43,417,017 | 44.1% | 10,092 |
| 2004 | 4,487,885 | 44,861,938 | 45.9% | 9,996 |
| 2003 | 4,023,173 | 40,734,467 | 41.3% | 10,125 |
| 2002 | 4,133,979 | 42,160,118 | 42.4% | 10,198 |
| 2001 | 4,124,241 | 41,302,969 | 42.3% | 10,015 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.