- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Arapahoe Combustion Turbine Project: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Arapahoe Combustion Turbine Project
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 18% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2000
- Net generation, 2025
- 310,442 MWh
- Grid
- 115 kV to Public Service Co of Colorado (PSCO)
- Location
- Denver County, Colorado
- Operated by
- SWG Arapahoe, LLC
Operations
- Net generation, 2025
- 310,442
MWh - Fuel burned, 2025
- 2,800,565
MMBtu - Capacity factor, 2025
- 18.3
% - Heat rate, 2025
- 9,021
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 309,518 | 2,736,480 | — | 8,841 |
| 2025 | 310,442 | 2,800,565 | 18.3% | 9,021 |
| 2024 | 249,406 | 2,273,231 | 14.6% | 9,115 |
| 2023 | 219,074 | 1,989,626 | 12.9% | 9,082 |
| 2022 | 225,984 | 2,082,936 | 13.3% | 9,217 |
| 2021 | 202,945 | 1,839,576 | 11.9% | 9,064 |
| 2020 | 207,742 | 1,926,366 | 12.2% | 9,273 |
| 2019 | 208,361 | 1,876,635 | 12.3% | 9,007 |
| 2018 | 250,560 | 2,251,299 | 14.7% | 8,985 |
| 2017 | 184,229 | 1,700,239 | 10.8% | 9,229 |
| 2016 | 59,277 | 553,831 | 3.5% | 9,343 |
| 2015 | 118,302 | 1,088,543 | 7.0% | 9,201 |
| 2014 | 192,959 | 1,751,559 | 11.3% | 9,077 |
| 2013 | 21,504 | 190,409 | 1.3% | 8,855 |
| 2012 | 89,568 | 796,694 | 5.3% | 8,895 |
| 2011 | 178,752 | 1,584,926 | 10.5% | 8,867 |
| 2010 | 190,272 | 1,668,994 | 11.2% | 8,772 |
| 2009 | 302,690 | 2,635,856 | 17.8% | 8,708 |
| 2008 | 266,879 | 2,333,614 | 15.7% | 8,744 |
| 2007 | 269,760 | 2,315,817 | 15.9% | 8,585 |
| 2006 | 190,724 | 1,637,974 | 11.2% | 8,588 |
| 2005 | 231,275 | 2,042,367 | 13.6% | 8,831 |
| 2004 | 155,167 | 1,419,080 | 9.1% | 9,146 |
| 2003 | 294,997 | 2,453,964 | 17.4% | 8,319 |
| 2002 | 107,760 | 1,230,485 | 6.3% | 11,419 |
| 2001 | 95,721 | 1,070,785 | 5.6% | 11,186 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.