Archer Daniels Midland Lincoln
Power plant · Gas, steam turbine
Key facts
Power plant · Gas, steam turbineran 65% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1988
- Net generation, 2025
- 44,880 MWh
- Grid
- 35 kV to Lincoln Electric System (SWPP)
- Location
- Lancaster County, Nebraska
- Operated by
- Archer Daniels MidlandSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 44,880
MWh - Fuel burned, 2025
- 1,550,130
MMBtu - Capacity factor, 2025
- 64.8
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 44,880 | 1,550,130 | 64.8% | — |
| 2024 | 10,956 | 134,678 | 15.8% | 12,293 |
| 2023 | 9,012 | 688,593 | 13.0% | — |
| 2022 | 30,432 | 1,374,032 | 44.0% | — |
| 2021 | 29,352 | 1,103,344 | 42.4% | — |
| 2020 | 30,888 | 1,548,753 | 44.5% | — |
| 2019 | 26,882 | 1,308,513 | 38.8% | — |
| 2018 | 29,535 | 1,468,952 | 42.7% | — |
| 2017 | 27,122 | 1,300,954 | 39.2% | — |
| 2016 | 35,318 | 1,237,534 | 50.9% | — |
| 2015 | 46,088 | 1,524,393 | 66.6% | — |
| 2014 | 41,886 | 1,439,343 | 60.5% | — |
| 2013 | 40,894 | 1,379,912 | 59.1% | — |
| 2012 | 46,088 | 1,465,450 | 66.4% | — |
| 2011 | 41,239 | 1,397,562 | 59.6% | — |
| 2010 | 46,065 | 1,517,349 | 66.6% | — |
| 2009 | 42,034 | 1,623,848 | 60.7% | — |
| 2008 | 49 | 0 | 0.1% | — |
| 2007 | 18,062 | 919,685 | 26.1% | — |
| 2006 | 49,693 | 1,601,233 | 71.8% | — |
| 2005 | 45,581 | 1,536,500 | 65.9% | — |
| 2004 | 42,125 | 1,402,100 | 60.7% | — |
| 2002 | 44,104 | 1,405,339 | 63.7% | — |
| 2001 | 45,164 | 1,441,853 | 65.3% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.