- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Argyle: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Argyle
Power plant · Oil
Key facts
Power plant · Oilran 1% of 2025 Standby- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1929
- Net generation, 2025
- 193 MWh
- Grid
- 69 kV to City of Argyle - (WI) (MISO)
- Location
- Lafayette County, Wisconsin
- Operated by
- City of Argyle - (WI)SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 193
MWh - Fuel burned, 2025
- 755
MMBtu - Capacity factor, 2025
- 1.0
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 193 | 755 | 1.0% | — |
| 2024 | 24 | 107 | 0.1% | — |
| 2023 | 10 | 82 | 0.1% | 8,200 |
| 2022 | 8 | 87 | 0.0% | 10,875 |
| 2021 | 217 | 1,938 | 1.1% | 8,931 |
| 2020 | 128 | 1,143 | 0.6% | 8,930 |
| 2019 | 68 | 665 | 0.3% | 9,779 |
| 2018 | 134 | 1,235 | 0.7% | 9,216 |
| 2017 | 171 | 1,584 | 0.9% | 9,263 |
| 2016 | 171 | 1,586 | 0.9% | 9,275 |
| 2015 | 183 | 1,739 | 0.9% | 9,503 |
| 2014 | 203 | 1,943 | 1.0% | 9,571 |
| 2013 | 149 | 1,423 | 0.7% | 9,550 |
| 2012 | 151 | 1,475 | 0.8% | 9,768 |
| 2011 | 223 | 2,175 | 1.1% | 9,753 |
| 2010 | 177 | 1,735 | 0.9% | 9,802 |
| 2009 | 177 | 1,704 | 0.9% | 9,627 |
| 2008 | 91 | 903 | 0.4% | 9,923 |
| 2007 | 170 | 1,689 | 0.8% | 9,935 |
| 2006 | 211 | 2,104 | 1.1% | 9,972 |
| 2005 | 230 | 2,312 | 1.1% | 10,054 |
| 2004 | 255 | 2,577 | 1.3% | 10,105 |
| 2003 | 233 | 2,161 | 1.2% | 9,273 |
| 2002 | 261 | 2,795 | 1.3% | 10,708 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
2 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)