- Combustion
- Retired
- 10 · 100 · 1,000 MW
Map
- Combustion
- Retired
Astoria Gas Turbines: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Astoria Gas Turbines
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbine Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1970
- Net generation, 2025
- 0 MWh
- Location
- Queens County, New York
- Operated by
- NRG Astoria Gas Turbine Operations Inc
Operations
- Net generation, 2025
- 0
MWh - Fuel burned, 2025
- 0
MMBtu - Capacity factor, 2025
- Not stated
- Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 0 | 0 | — | — |
| 2024 | 0 | 0 | — | — |
| 2023 (5 of 12 months) | 4,902 | 70,454 | — | 14,372 |
| 2022 | 48,051 | 693,723 | 0.8% | 14,437 |
| 2021 | 37,394 | 547,743 | 0.6% | 14,648 |
| 2020 | 19,797 | 290,706 | 0.3% | 14,684 |
| 2019 | 17,047 | 254,668 | 0.3% | 14,939 |
| 2018 | 39,732 | 590,434 | 0.7% | 14,860 |
| 2017 | 29,460 | 435,254 | 0.5% | 14,774 |
| 2016 | 48,144 | 715,638 | 0.8% | 14,864 |
| 2015 | 38,529 | 566,246 | 0.7% | 14,697 |
| 2014 | 54,276 | 783,992 | 0.9% | 14,444 |
| 2013 | 58,034 | 861,295 | 1.0% | 14,841 |
| 2012 | 94,135 | 1,371,426 | 1.6% | 14,569 |
| 2011 | 50,045 | 741,186 | 0.9% | 14,810 |
| 2010 | 36,093 | 533,849 | 0.6% | 14,791 |
| 2009 | 35,213 | 516,689 | 0.6% | 14,673 |
| 2008 | 103,494 | 1,495,259 | 1.8% | 14,448 |
| 2007 | 71,950 | 1,047,111 | 1.2% | 14,553 |
| 2006 | 106,601 | 1,569,091 | 1.8% | 14,719 |
| 2005 | 364,073 | 5,428,288 | 6.2% | 14,910 |
| 2004 | 214,433 | 3,158,891 | 3.7% | 14,731 |
| 2003 | 197,725 | 2,888,113 | 3.4% | 14,607 |
| 2002 | 220,898 | 3,413,135 | 3.8% | 15,451 |
| 2001 | 195,325 | 2,952,650 | 3.4% | 15,117 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.