Barry
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 48% of 2024 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1954
- Net generation, 2024
- 14,055,869 MWh
- Grid
- 230 kV to Alabama Power Co (SOCO)
- Location
- Mobile County, Alabama
- Operated by
- Alabama Power Co
Operations
- Net generation, 2024
- 14,055,869
MWh - Fuel burned, 2024
- 100,026,786
MMBtu - Capacity factor, 2024
- 47.9
% - Heat rate, 2024
- 7,116
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 9,535,991 | 68,519,048 | — | 7,185 |
| 2025 (11 of 12 months) | 12,486,289 | 90,208,661 | — | 7,225 |
| 2024 | 14,055,869 | 100,026,786 | 47.9% | 7,116 |
| 2023 (11 of 12 months) | 8,675,796 | 68,868,250 | — | 7,938 |
| 2022 | 11,894,419 | 95,482,811 | 40.6% | 8,028 |
| 2021 | 11,792,286 | 94,466,581 | 40.3% | 8,011 |
| 2020 (11 of 12 months) | 10,499,146 | 82,061,242 | — | 7,816 |
| 2019 | 12,470,807 | 100,290,242 | 42.6% | 8,042 |
| 2018 (10 of 12 months) | 10,464,916 | 85,184,794 | — | 8,140 |
| 2017 | 11,864,554 | 93,645,595 | 40.5% | 7,893 |
| 2016 | 12,770,891 | 102,749,785 | 43.5% | 8,046 |
| 2015 | 11,387,562 | 94,524,126 | 38.9% | 8,301 |
| 2014 | 12,981,029 | 108,997,771 | 44.3% | 8,397 |
| 2013 | 12,897,137 | 107,369,101 | 44.0% | 8,325 |
| 2012 | 13,262,529 | 110,641,711 | 45.2% | 8,342 |
| 2011 | 12,354,231 | 102,443,454 | 42.2% | 8,292 |
| 2010 | 15,188,887 | 130,194,864 | 51.9% | 8,572 |
| 2009 | 14,086,902 | 122,482,205 | 48.1% | 8,695 |
| 2008 | 14,027,352 | 127,526,553 | 47.8% | 9,091 |
| 2007 | 15,152,333 | 143,831,966 | 51.7% | 9,492 |
| 2006 | 14,639,481 | 142,227,018 | 50.0% | 9,715 |
| 2005 | 14,601,276 | 142,566,542 | 49.9% | 9,764 |
| 2004 | 14,435,331 | 135,689,639 | 49.1% | 9,400 |
| 2003 | 14,816,364 | 137,625,950 | 50.6% | 9,289 |
| 2002 | 16,941,194 | 152,864,341 | 57.8% | 9,023 |
| 2001 | 15,798,765 | 142,176,912 | 53.9% | 8,999 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.