Show on map
Beaver — Power plant · Gas, combined cycle · Portland General Electric Co
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Power plant · Gas, combined cycle

Key facts

Power plant · Gas, combined cycleran 36% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1974
Net generation, 2025
1,904,190 MWh
Grid
230 kV to Portland General Electric Co (PGE)
Location
Columbia County, Oregon
Operated by
Portland General Electric CoSourceEIA-860M Preliminary Monthly Electric Generator Inventory

Operations

Net generation, 2025
1,904,190MWh
Fuel burned, 2025
18,562,994MMBtu
Capacity factor, 2025
35.6%
Heat rate, 2025
9,748Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
20251,904,19018,562,99435.6%9,748
20241,713,19017,668,43331.9%10,313
20231,691,84917,242,98731.6%10,192
2022872,9858,913,05316.3%10,210
2021841,6438,545,78315.7%10,154
2020376,8733,894,9967.0%10,335
2019500,5515,174,1779.4%10,337
2018495,5785,114,0479.3%10,319
2017369,9403,840,5646.9%10,382
2016457,4744,539,0018.5%9,922
2015 (10 of 12 months)313,2213,308,148—10,562
2014206,1012,182,1833.9%10,588
2013273,0342,828,4195.1%10,359
2012 (11 of 12 months)26,090355,077—13,610
201146,963599,3870.9%12,763
2010156,6201,642,7582.9%10,489
2009450,1654,438,3018.4%9,859
2008140,9551,523,5412.6%10,809
2007362,9033,606,9236.8%9,939
2006340,4543,426,1716.4%10,064
2005157,5981,693,6762.9%10,747
2004374,9534,014,5747.0%10,707
2003 (9 of 12 months)271,4573,534,981—13,022
2002544,8136,515,50310.2%11,959
20013,329,50332,813,07062.2%9,855
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

2 sources

Sources EIA-860M · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source