- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Bluffview: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Bluffview
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 55% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2005
- Net generation, 2025
- 411,510 MWh
- Grid
- 115 kV to City of Farmington - (NM) (WACM)
- Location
- San Juan County, New Mexico
- Operated by
- City of Farmington - (NM)
Operations
- Net generation, 2025
- 411,510
MWh - Fuel burned, 2025
- 3,449,463
MMBtu - Capacity factor, 2025
- 54.8
% - Heat rate, 2025
- 8,382
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 411,510 | 3,449,463 | 54.8% | 8,382 |
| 2024 | 286,534 | 2,248,253 | 38.0% | 7,846 |
| 2023 | 428,612 | 3,438,642 | 57.0% | 8,023 |
| 2022 | 294,719 | 2,292,068 | 39.2% | 7,777 |
| 2021 | 308,921 | 2,423,233 | 41.1% | 7,844 |
| 2020 | 393,780 | 3,091,430 | 52.2% | 7,851 |
| 2019 | 398,748 | 3,110,548 | 53.0% | 7,801 |
| 2018 | 371,595 | 2,914,546 | 49.4% | 7,843 |
| 2017 | 417,712 | 3,279,338 | 55.6% | 7,851 |
| 2016 | 422,722 | 3,226,331 | 56.1% | 7,632 |
| 2015 | 332,409 | 2,760,613 | 44.2% | 8,305 |
| 2014 | 328,679 | 2,587,617 | 43.7% | 7,873 |
| 2013 | 350,580 | 2,826,059 | 46.6% | 8,061 |
| 2012 | 463,605 | 3,687,844 | 61.5% | 7,955 |
| 2011 | 232,583 | 1,861,353 | 30.9% | 8,003 |
| 2010 | 421,331 | 3,332,490 | 56.1% | 7,909 |
| 2009 | 454,053 | 4,081,439 | 60.4% | 8,989 |
| 2008 | 438,543 | 3,484,816 | 58.2% | 7,946 |
| 2007 | 424,772 | 3,403,418 | 56.5% | 8,012 |
| 2006 | 445,854 | 3,430,803 | 59.3% | 7,695 |
| 2005 | 302,461 | 1,800,378 | 40.2% | 5,952 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- Global Energy Monitor — Global Integrated Power Tracker (unit-level power plants, eight technologies, all statuses)Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)