- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Clover: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Clover
Power plant · Coal
Key facts
Power plant · Coalran 22% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1995
- Net generation, 2025
- 1,643,625 MWh
- Grid
- 230 kV to Virginia Electric & Power Co (PJM)
- Location
- Halifax County, Virginia
- Operated by
- Virginia Electric & Power Co
Operations
- Net generation, 2025
- 1,643,625
MWh - Fuel burned, 2025
- 18,162,515
MMBtu - Capacity factor, 2025
- 22.1
% - Heat rate, 2025
- 11,050
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 990,563 | 9,737,721 | — | 9,830 |
| 2025 | 1,643,625 | 18,162,515 | 22.1% | 11,050 |
| 2024 | 908,475 | 10,375,041 | 12.2% | 11,420 |
| 2023 | 247,929 | 2,962,922 | 3.3% | 11,951 |
| 2022 | 631,232 | 7,038,995 | 8.5% | 11,151 |
| 2021 | 892,660 | 10,122,664 | 12.0% | 11,340 |
| 2020 | 1,240,625 | 13,201,603 | 16.7% | 10,641 |
| 2019 | 1,281,310 | 13,484,455 | 17.2% | 10,524 |
| 2018 | 2,917,180 | 29,879,765 | 39.3% | 10,243 |
| 2017 | 3,266,582 | 33,629,444 | 44.0% | 10,295 |
| 2016 | 5,444,917 | 54,842,948 | 73.1% | 10,072 |
| 2015 | 5,484,916 | 54,857,444 | 73.8% | 10,002 |
| 2014 | 5,678,306 | 56,909,561 | 76.4% | 10,022 |
| 2013 | 5,919,319 | 59,204,161 | 79.7% | 10,002 |
| 2012 | 4,400,124 | 44,134,339 | 59.1% | 10,030 |
| 2011 | 5,176,732 | 52,669,012 | 69.7% | 10,174 |
| 2010 | 6,193,652 | 61,696,380 | 83.4% | 9,961 |
| 2009 | 5,587,711 | 55,604,216 | 75.2% | 9,951 |
| 2008 | 5,809,328 | 57,636,515 | 78.0% | 9,921 |
| 2007 | 6,676,803 | 65,389,225 | 89.9% | 9,794 |
| 2006 | 6,942,867 | 67,825,734 | 93.5% | 9,769 |
| 2005 | 6,386,114 | 59,209,083 | 86.0% | 9,272 |
| 2004 | 6,685,138 | 63,344,451 | 89.8% | 9,475 |
| 2003 | 6,424,844 | 60,355,533 | 86.5% | 9,394 |
| 2002 | 6,307,712 | 61,392,145 | 84.9% | 9,733 |
| 2001 | 6,684,781 | 65,232,562 | 90.0% | 9,758 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)