- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
CM10: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
CM10
Power plant · Solar
Key facts
Power plant · Solarran 21% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2008
- Net generation, 2025
- 18,355 MWh
- Grid
- 230 kV to San Diego Gas & Electric Co (CISO)
- Location
- Clark County, Nevada
- Operated by
- RWE Americas, LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 18,355
MWh - Fuel burned, 2025
- 62,627
MMBtu - Capacity factor, 2025
- 20.9
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 18,355 | 62,627 | 20.9% | — |
| 2024 | 17,988 | 61,374 | 20.5% | — |
| 2023 | 19,201 | 65,514 | 21.9% | — |
| 2022 | 18,948 | 64,649 | 21.6% | — |
| 2021 | 18,686 | 165,259 | 21.3% | — |
| 2020 | 21,953 | 192,462 | 25.0% | — |
| 2019 | 22,562 | 200,916 | 25.8% | — |
| 2018 | 19,595 | 178,392 | 22.4% | — |
| 2017 | 19,321 | 178,004 | 22.1% | — |
| 2016 | 19,061 | 175,969 | 21.7% | — |
| 2015 | 19,885 | 185,309 | 22.7% | — |
| 2014 | 19,869 | 188,953 | 22.7% | — |
| 2013 | 20,375 | 194,399 | 23.3% | — |
| 2012 | 21,245 | 202,168 | 24.2% | — |
| 2011 | 21,546 | 209,341 | 24.6% | — |
| 2010 | 21,146 | 206,300 | 24.1% | — |
| 2009 | 21,661 | 211,412 | 24.7% | — |
| 2008 | 826 | 8,139 | 0.9% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)