- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Comanche (OK): location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Comanche (OK)
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 13% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1962
- Net generation, 2025
- 331,292 MWh
- Grid
- 138 kV to Public Service Co of Oklahoma (SWPP)
- Location
- Comanche County, Oklahoma
- Operated by
- Public Service Co of Oklahoma
Operations
- Net generation, 2025
- 331,292
MWh - Fuel burned, 2025
- 3,083,642
MMBtu - Capacity factor, 2025
- 12.9
% - Heat rate, 2025
- 9,308
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 331,292 | 3,083,642 | 12.9% | 9,308 |
| 2024 | 500,643 | 4,770,665 | 19.4% | 9,529 |
| 2023 | 511,873 | 4,772,046 | 19.9% | 9,323 |
| 2022 | 284,855 | 2,690,276 | 11.1% | 9,444 |
| 2021 | 218,525 | 2,065,277 | 8.5% | 9,451 |
| 2020 | 243,256 | 2,268,953 | 9.4% | 9,327 |
| 2019 | 276,010 | 2,554,321 | 10.7% | 9,254 |
| 2018 | 196,644 | 1,865,796 | 7.6% | 9,488 |
| 2016 | 95,049 | 902,460 | 3.7% | 9,495 |
| 2015 | 363,326 | 3,384,640 | 14.1% | 9,316 |
| 2014 | 487,999 | 4,607,016 | 18.9% | 9,441 |
| 2013 | 742,569 | 7,067,022 | 28.8% | 9,517 |
| 2012 | 979,535 | 9,027,491 | 37.9% | 9,216 |
| 2011 | 790,552 | 7,365,261 | 30.7% | 9,317 |
| 2010 | 916,723 | 8,491,853 | 35.6% | 9,263 |
| 2009 | 844,730 | 7,773,356 | 32.8% | 9,202 |
| 2008 | 1,248,513 | 11,902,333 | 48.4% | 9,533 |
| 2007 | 1,044,246 | 9,903,999 | 40.6% | 9,484 |
| 2006 | 996,377 | 9,813,961 | 38.7% | 9,850 |
| 2005 | 1,210,818 | 11,490,529 | 47.0% | 9,490 |
| 2004 | 1,165,391 | 11,311,380 | 45.1% | 9,706 |
| 2003 | 1,294,882 | 12,099,319 | 50.3% | 9,344 |
| 2002 | 1,338,064 | 12,401,678 | 51.9% | 9,268 |
| 2001 | 1,204,166 | 11,081,822 | 46.8% | 9,203 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.