Power plant · Coal
Key facts
Power plant · Coalran 23% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1970
- Net generation, 2025
- 3,910,290 MWh
- Grid
- 500 kV to Pennsylvania Electric Co (PJM)
- Location
- Indiana County, Pennsylvania
- Operated by
- Keycon Operating LLC
Operations
- Net generation, 2025
- 3,910,290
MWh - Fuel burned, 2025
- 40,552,098
MMBtu - Capacity factor, 2025
- 22.7
% - Heat rate, 2025
- 10,371
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 3,279,894 | 32,919,509 | — | 10,037 |
| 2025 | 3,910,290 | 40,552,098 | 22.7% | 10,371 |
| 2024 | 3,586,738 | 37,543,919 | 20.8% | 10,467 |
| 2023 | 2,859,335 | 30,141,745 | 16.6% | 10,542 |
| 2022 | 5,715,098 | 58,433,721 | 33.2% | 10,224 |
| 2021 | 7,263,164 | 74,249,138 | 42.2% | 10,223 |
| 2020 | 7,530,024 | 74,504,578 | 43.7% | 9,894 |
| 2019 | 11,005,565 | 105,664,683 | 64.0% | 9,601 |
| 2018 | 11,445,473 | 109,805,213 | 66.6% | 9,594 |
| 2017 | 11,268,609 | 109,207,597 | 65.5% | 9,691 |
| 2016 | 9,219,006 | 91,417,589 | 53.5% | 9,916 |
| 2015 | 11,147,023 | 108,861,968 | 64.8% | 9,766 |
| 2014 | 11,005,436 | 107,688,075 | 64.0% | 9,785 |
| 2013 | 11,759,883 | 113,580,799 | 68.4% | 9,658 |
| 2012 | 10,626,350 | 103,472,696 | 61.6% | 9,737 |
| 2011 | 10,810,982 | 105,809,383 | 62.9% | 9,787 |
| 2010 | 12,162,111 | 117,342,424 | 70.7% | 9,648 |
| 2009 | 12,155,841 | 115,895,700 | 70.7% | 9,534 |
| 2008 | 11,474,911 | 108,810,077 | 66.5% | 9,482 |
| 2007 | 12,956,157 | 123,002,009 | 75.3% | 9,494 |
| 2006 | 14,290,006 | 135,404,168 | 83.1% | 9,475 |
| 2005 | 12,942,074 | 121,239,467 | 75.3% | 9,368 |
| 2004 | 13,024,335 | 121,486,216 | 75.5% | 9,328 |
| 2003 (11 of 12 months) | 12,422,421 | 116,092,470 | — | 9,345 |
| 2002 | 12,656,276 | 128,846,193 | 73.6% | 10,180 |
| 2001 | 12,735,356 | 121,001,173 | 74.1% | 9,501 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)