Show on map
Cooper — Power plant · Coal · East Kentucky Power Coop, Inc
  • Combustion
  • Operating
  • 10 · 100 · 1,000 MW

Power plant · Coal

Key facts

Power plant · Coalran 17% of 2025 Operating
Capacity
Capacity: sourceEIA-860M · Open licenseMW
Commissioned
1965
Net generation, 2025
516,184 MWh
Grid
161 kV, 69 kV to East Kentucky Power Coop, Inc (PJM)
Location
Pulaski County, Kentucky
Operated by
East Kentucky Power Coop, IncSourceEIA-860M Preliminary Monthly Electric Generator Inventory

Operations

Net generation, 2025
516,184MWh
Fuel burned, 2025
5,638,936MMBtu
Capacity factor, 2025
17.1%
Heat rate, 2025
10,924Btu/kWh
Capacity factor % of full output, by year
Heat rate Btu per kWh, by year
Net generation, fuel burned, capacity factor and heat rate by year, newest first, as EIA's bulk electricity file states them.
YearNet generation (MWh)Fuel burned (MMBtu)Capacity factorHeat rate (Btu/kWh)
2026 (8 of 12 months)567,8606,215,262—10,945
2025516,1845,638,93617.1%10,924
2024441,1414,830,87214.6%10,951
2023477,4715,075,34315.8%10,630
2022549,2826,018,56418.2%10,957
2021478,6125,303,17815.9%11,080
2020142,5071,736,2434.7%12,184
2019168,6102,020,4195.6%11,983
2018562,0906,045,68618.6%10,756
2017446,7584,831,02814.8%10,814
2016644,6566,833,36721.3%10,600
2015 (10 of 12 months)524,5095,647,537—10,767
20141,029,44011,077,19634.2%10,760
2013997,37510,903,06933.1%10,932
20121,462,88515,648,37448.4%10,697
20111,696,77017,909,08756.3%10,555
20101,835,27420,279,65660.9%11,050
20091,584,81216,800,59652.6%10,601
20082,084,20721,562,26969.0%10,346
20071,957,04220,309,48464.9%10,378
20061,972,45520,314,40865.5%10,299
20052,003,93120,317,19866.5%10,139
20042,275,19823,012,32275.3%10,114
20031,867,67918,843,32862.0%10,089
20022,100,20821,448,38169.7%10,212
20012,137,24721,796,58070.9%10,198
How these are worked out

Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.

Sources

3 sources

Sources EIA-860M · GEM · EIA

Sources

  • EIA-860MOpen license · retrieved Nov 4, 2026
  • GEMOpen license, with credit · retrieved Oct 26, 2026Global Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
  • EIAOpen license · retrieved Nov 1, 2026Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)

Every source and license · Attribution

View at source