- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Copper: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Copper
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 4% of 2025 Retiring- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1980
- Net generation, 2025
- 27,840 MWh
- Grid
- 115 kV to El Paso Electric Co (EPE)
- Location
- El Paso County, Texas
- Operated by
- El Paso Electric CoSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 27,840
MWh - Fuel burned, 2025
- 486,438
MMBtu - Capacity factor, 2025
- 3.7
% - Heat rate, 2025
- 17,473
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 27,840 | 486,438 | 3.7% | 17,473 |
| 2024 | 49,822 | 902,714 | 6.5% | 18,119 |
| 2023 | 48,678 | 914,423 | 6.4% | 18,785 |
| 2022 | 47,291 | 918,953 | 6.2% | 19,432 |
| 2021 | 28,972 | 571,208 | 3.8% | 19,716 |
| 2020 | 33,888 | 665,721 | 4.4% | 19,645 |
| 2019 | 39,534 | 688,550 | 5.2% | 17,417 |
| 2018 | 47,287 | 780,895 | 6.2% | 16,514 |
| 2017 | 18,913 | 357,032 | 2.5% | 18,878 |
| 2016 | 33,073 | 546,763 | 4.3% | 16,532 |
| 2015 | 24,907 | 441,224 | 3.3% | 17,715 |
| 2014 | 39,856 | 651,213 | 5.2% | 16,339 |
| 2013 | 37,561 | 631,566 | 4.9% | 16,814 |
| 2012 | 37,420 | 710,420 | 4.9% | 18,985 |
| 2011 | 38,997 | 687,879 | 5.1% | 17,639 |
| 2010 | 14,522 | 228,261 | 1.9% | 15,718 |
| 2009 | 17,415 | 225,529 | 2.3% | 12,950 |
| 2008 | 18,110 | 301,013 | 2.4% | 16,621 |
| 2007 | 16,046 | 260,420 | 2.1% | 16,230 |
| 2006 | 16,420 | 267,636 | 2.2% | 16,299 |
| 2005 | 16,463 | 267,214 | 2.2% | 16,231 |
| 2004 | 6,156 | 106,802 | 0.8% | 17,349 |
| 2003 | 11,201 | 176,674 | 1.5% | 15,773 |
| 2002 | 24,609 | 329,281 | 3.2% | 13,380 |
| 2001 | 129,181 | 1,903,496 | 17.0% | 14,735 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)