Covanta Indianapolis Energy
Power plant · Waste to energy
Key facts
Power plant · Waste to energy Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1988
- Net generation, 2025
- 0 MWh
- Grid
- 34 kV to Indianapolis Power & Light Co (MISO)
- Location
- Marion County, Indiana
- Operated by
- Reworld Indianapolis Inc
Operations
- Net generation, 2025
- 0
MWh - Fuel burned, 2025
- 7,949,312
MMBtu - Capacity factor, 2025
- Not stated
- Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 0 | 5,498,913 | — | — |
| 2025 | 0 | 7,949,312 | — | — |
| 2024 | 0 | 7,765,927 | — | — |
| 2023 | 0 | 7,656,879 | — | — |
| 2022 | 22,534 | 7,551,838 | 39.6% | — |
| 2021 | 41,938 | 7,369,810 | 73.7% | — |
| 2020 | 44,616 | 7,537,669 | 78.1% | — |
| 2019 | 44,177 | 7,071,417 | 77.6% | — |
| 2018 | 45,083 | 7,347,181 | 79.2% | — |
| 2017 | 40,612 | 6,988,127 | 71.3% | — |
| 2016 | 40,304 | 7,225,504 | 70.6% | — |
| 2015 | 41,024 | 7,078,295 | 72.0% | — |
| 2014 | 39,717 | 5,951,366 | 69.8% | — |
| 2013 | 40,105 | 6,641,757 | 70.4% | — |
| 2012 | 41,512 | 7,863,169 | 72.7% | — |
| 2011 | 39,507 | 7,779,064 | 69.4% | — |
| 2010 | 39,901 | 8,255,263 | 70.1% | — |
| 2009 | 37,135 | 8,158,526 | 65.2% | — |
| 2008 | 41,269 | 8,396,909 | 72.3% | — |
| 2007 | 34,342 | 1,349,981 | 60.3% | — |
| 2006 | 40,053 | 7,239,142 | 70.3% | — |
| 2005 | 39,725 | 7,169,805 | 69.8% | — |
| 2004 | 39,722 | 7,431,701 | 69.6% | — |
| 2002 | 35,719 | 7,167,398 | 62.7% | — |
| 2001 | 37,288 | 7,186,127 | 65.5% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.