- Combustion
- Retired
- 10 · 100 · 1,000 MW
Map
- Combustion
- Retired
Cudjoe: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Cudjoe
Power plant · Oil
Key facts
Power plant · Oilran 2% of 2005 Retired- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1966
- Net generation, 2005
- 735 MWh
- Location
- Monroe County, Florida
- Operated by
- Utility Board of Key West City (FL)SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2005
- 735
MWh - Fuel burned, 2005
- 8,482
MMBtu - Capacity factor, 2005
- 1.7
% - Heat rate, 2005
- 11,540
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2006 (11 of 12 months) | 92 | 1,074 | — | 11,674 |
| 2005 | 735 | 8,482 | 1.7% | 11,540 |
| 2004 | 235 | 2,717 | 0.5% | 11,562 |
| 2003 | 3,448 | 38,572 | 7.9% | 11,187 |
| 2002 | 1,721 | 20,668 | 3.9% | 12,009 |
| 2001 | 1,995 | 23,280 | 4.5% | 11,669 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.