- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Dahlberg: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Dahlberg
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 4% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2000
- Net generation, 2025
- 286,500 MWh
- Grid
- 230 kV to Georgia Power Co (SOCO)
- Location
- Jackson County, Georgia
- Operated by
- Southern Power Co
Operations
- Net generation, 2025
- 286,500
MWh - Fuel burned, 2025
- 3,491,460
MMBtu - Capacity factor, 2025
- 3.6
% - Heat rate, 2025
- 12,187
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 286,500 | 3,491,460 | 3.6% | 12,187 |
| 2024 | 229,368 | 2,799,800 | 2.8% | 12,207 |
| 2023 | 242,812 | 2,966,943 | 3.0% | 12,219 |
| 2022 | 316,264 | 3,575,802 | 3.9% | 11,306 |
| 2021 | 185,211 | 2,276,880 | 2.3% | 12,293 |
| 2020 | 512,046 | 6,239,451 | 6.3% | 12,185 |
| 2019 | 488,534 | 5,966,395 | 6.1% | 12,213 |
| 2018 | 410,888 | 5,049,357 | 5.1% | 12,289 |
| 2017 | 326,512 | 3,969,739 | 4.1% | 12,158 |
| 2016 | 598,501 | 7,238,371 | 7.4% | 12,094 |
| 2015 | 511,871 | 6,184,042 | 6.4% | 12,081 |
| 2014 | 338,572 | 4,077,258 | 4.2% | 12,042 |
| 2013 | 127,676 | 1,534,009 | 1.6% | 12,015 |
| 2012 | 372,074 | 4,501,382 | 4.6% | 12,098 |
| 2011 | 190,603 | 2,350,767 | 2.4% | 12,333 |
| 2010 | 284,271 | 3,489,873 | 3.5% | 12,277 |
| 2009 | 195,043 | 2,390,239 | 2.4% | 12,255 |
| 2008 | 123,285 | 1,574,226 | 1.5% | 12,769 |
| 2007 | 249,986 | 3,088,984 | 3.1% | 12,357 |
| 2006 | 85,833 | 1,095,655 | 1.1% | 12,765 |
| 2005 | 91,319 | 1,164,593 | 1.1% | 12,753 |
| 2004 | 78,353 | 1,001,179 | 1.0% | 12,778 |
| 2003 | 86,431 | 1,069,022 | 1.1% | 12,368 |
| 2002 | 291,965 | 3,648,789 | 3.6% | 12,497 |
| 2001 | 206,207 | 2,529,217 | 2.6% | 12,265 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.