Des Moines Wastewater Reclamation Fac
Power plant · Biomass
Key facts
Power plant · Biomassran 0% of 2025 Standby- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2015
- Net generation, 2025
- 74 MWh
- Grid
- 13 kV to MidAmerican Energy Co (MISO)
- Location
- Polk County, Iowa
- Operated by
- Des Moines Metro WRFSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 74
MWh - Fuel burned, 2025
- 799
MMBtu - Capacity factor, 2025
- 0.3
% - Heat rate, 2025
- 10,728
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 74 | 799 | 0.3% | 10,728 |
| 2024 | 71 | 752 | 0.3% | 10,658 |
| 2023 | 73 | 778 | 0.3% | 10,728 |
| 2022 | 76 | 706 | 0.3% | 9,236 |
| 2021 | 135 | 1,165 | 0.5% | 8,614 |
| 2020 | 1,492 | 17,850 | 6.1% | 11,964 |
| 2019 | 16,174 | 210,184 | 65.9% | 12,995 |
| 2018 | 14,319 | 189,098 | 58.4% | 13,206 |
| 2017 | 7,471 | 106,028 | 30.5% | 14,192 |
| 2016 | 22,337 | 61,471 | 90.8% | — |
| 2015 | 14,574 | 175,676 | 59.4% | 12,054 |
| 2014 | 12,379 | 151,013 | 50.5% | 12,199 |
| 2013 | 13,335 | 152,636 | 54.4% | 11,446 |
| 2012 | 10,695 | 110,635 | 43.5% | 10,345 |
| 2011 | 12,349 | 163,913 | 50.3% | 13,273 |
| 2010 | 9,631 | 120,070 | 39.3% | 12,466 |
| 2009 | 7,887 | 114,786 | 32.2% | 14,554 |
| 2008 | 8,610 | 311 | 35.0% | — |
| 2007 | 9,543 | 122,763 | 38.9% | 12,864 |
| 2006 | 13,514 | 211,214 | 55.1% | 15,629 |
| 2005 | 12,431 | 258,580 | 50.7% | 20,801 |
| 2004 | 11,280 | 269,268 | 45.9% | 23,872 |
| 2003 | 13,016 | 254,949 | 53.1% | 19,587 |
| 2002 | 10,948 | 670,417 | 44.6% | — |
| 2001 | 11,316 | 193,830 | 46.1% | 17,129 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.