Echo Dam
Power plant · Hydro
Key facts
Power plant · Hydroran 22% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1987
- Net generation, 2025
- 8,647 MWh
- Grid
- 46 kV to City of Bountiful (PACE)
- Location
- Summit County, Utah
- Operated by
- City of Bountiful - (UT)SourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 8,647
MWh - Fuel burned, 2025
- 29,503
MMBtu - Capacity factor, 2025
- 22.4
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 8,647 | 29,503 | 22.4% | — |
| 2024 | 12,248 | 41,791 | 31.7% | — |
| 2023 | 12,930 | 44,117 | 33.6% | — |
| 2022 | 6,664 | 22,738 | 17.3% | — |
| 2021 | 1,153 | 10,197 | 3.0% | — |
| 2020 | 6,710 | 58,826 | 17.4% | — |
| 2019 | 7,400 | 65,896 | 19.2% | — |
| 2018 | 6,786 | 61,781 | 17.6% | — |
| 2017 | 11,863 | 109,293 | 30.8% | — |
| 2016 | 5,747 | 53,057 | 14.9% | — |
| 2015 | 5,673 | 52,866 | 14.7% | — |
| 2014 | 3,757 | 35,730 | 9.8% | — |
| 2013 | 2,475 | 23,616 | 6.4% | — |
| 2012 | 5,872 | 55,876 | 15.2% | — |
| 2011 | 19,868 | 193,037 | 51.5% | — |
| 2010 | 10,565 | 103,072 | 27.4% | — |
| 2009 | 13,463 | 131,401 | 34.9% | — |
| 2008 | 9,321 | 91,849 | 24.1% | — |
| 2007 | 7,623 | 75,347 | 19.8% | — |
| 2006 | 12,948 | 128,432 | 33.6% | — |
| 2005 | 13,317 | 133,157 | 34.5% | — |
| 2004 | 2,988 | 29,946 | 7.7% | — |
| 2003 | 3,932 | 40,268 | 10.2% | — |
| 2002 | 4,079 | 41,496 | 10.6% | — |
| 2001 | 5,451 | 56,325 | 14.1% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.