- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
Fenner Wind: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Fenner Wind
Power plant · Wind
Key facts
Power plant · Windran 29% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2001
- Net generation, 2025
- 75,750 MWh
- Grid
- 115 kV to Niagara Mohawk Power Corp. (NYIS)
- Location
- Madison County, New York
- Operated by
- CHI Energy IncSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 75,750
MWh - Fuel burned, 2025
- 258,459
MMBtu - Capacity factor, 2025
- 28.8
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 75,750 | 258,459 | 28.8% | — |
| 2024 | 64,361 | 219,599 | 24.4% | — |
| 2023 | 70,421 | 240,276 | 26.8% | — |
| 2022 | 87,083 | 297,127 | 33.1% | — |
| 2021 | 73,372 | 648,902 | 27.9% | — |
| 2020 | 62,122 | 544,624 | 23.6% | — |
| 2019 | 79,129 | 704,645 | 30.1% | — |
| 2018 | 53,873 | 490,458 | 20.5% | — |
| 2017 | 44,448 | 409,500 | 16.9% | — |
| 2016 | 62,451 | 576,548 | 23.7% | — |
| 2015 | 67,350 | 627,635 | 25.6% | — |
| 2014 | 67,944 | 646,148 | 25.9% | — |
| 2013 | 68,252 | 651,194 | 26.0% | — |
| 2012 | 58,567 | 557,322 | 22.2% | — |
| 2011 | 65,005 | 631,588 | 24.7% | — |
| 2010 | 26,064 | 254,281 | 9.9% | — |
| 2009 | 64,112 | 625,737 | 24.4% | — |
| 2008 | 70,930 | 698,945 | 26.9% | — |
| 2007 | 72,190 | 713,526 | 27.5% | — |
| 2006 | 77,273 | 766,472 | 29.4% | — |
| 2005 | 67,750 | 677,432 | 25.8% | — |
| 2004 | 78,376 | 785,484 | 29.7% | — |
| 2003 | 6,888 | 70,540 | 2.6% | — |
| 2002 | 46,490 | 472,943 | 17.7% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)