- Clean firm
- Operating
- 10 · 100 · 1,000 MW
Map
- Clean firm
- Operating
Foothill Feeder: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Foothill Feeder
Power plant · Hydro
Key facts
Power plant · Hydro Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1981
- Net generation, 2025
- 0 MWh
- Grid
- 66 kV to Southern California Edison Co (CISO)
- Location
- Los Angeles County, California
- Operated by
- Metropolitan Water District of S CASourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 0
MWh - Fuel burned, 2025
- 0
MMBtu - Capacity factor, 2025
- Not stated
- Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 0 | 0 | — | — |
| 2024 | 0 | 0 | — | — |
| 2023 | 19,634 | 66,991 | 24.9% | — |
| 2022 | 0 | 0 | — | — |
| 2021 | 24,241 | 214,389 | 30.8% | — |
| 2020 | 50,987 | 447,002 | 64.5% | — |
| 2019 | 44,336 | 394,813 | 56.2% | — |
| 2018 | 48,539 | 441,898 | 61.6% | — |
| 2017 | 52,669 | 485,240 | 66.8% | — |
| 2016 | 27,372 | 252,699 | 34.6% | — |
| 2015 | 0 | 0 | — | — |
| 2014 | 24,918 | 236,971 | 31.6% | — |
| 2013 | 59,567 | 568,328 | 75.5% | — |
| 2012 | 54,094 | 514,760 | 68.4% | — |
| 2011 | 50,686 | 492,463 | 64.3% | — |
| 2010 | 48,132 | 469,576 | 61.1% | — |
| 2009 | 49,062 | 478,845 | 62.2% | — |
| 2008 | 60,103 | 592,256 | 76.0% | — |
| 2007 | 45,457 | 449,297 | 57.7% | — |
| 2006 | 52,130 | 517,078 | 66.1% | — |
| 2005 | 65,582 | 655,754 | 83.2% | — |
| 2004 | 57,778 | 579,051 | 73.1% | — |
| 2003 | 64,262 | 658,107 | 81.5% | — |
| 2002 | 63,276 | 643,707 | 80.3% | — |
| 2001 | 59,774 | 617,645 | 75.8% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
2 sourcesSources
- EIA-860M Preliminary Monthly Electric Generator Inventory
- EIA Open Data bulk file — Electricity (ELEC.zip; monthly plant net generation and fuel consumption since 2001)Source: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)