- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Gaston County Renewable Energy Center: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Gaston County Renewable Energy Center
Power plant · Biomass
Key facts
Power plant · Biomassran 63% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2011
- Net generation, 2025
- 23,051 MWh
- Grid
- 14 kV to Rutherford Elec Member Corp (DUK)
- Location
- Gaston County, North Carolina
- Operated by
- Gaston County Solid Waste and Recycling DivisionSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 23,051
MWh - Fuel burned, 2025
- 267,719
MMBtu - Capacity factor, 2025
- 62.6
% - Heat rate, 2025
- 11,614
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 23,051 | 267,719 | 62.6% | 11,614 |
| 2024 | 19,768 | 238,219 | 53.6% | 12,051 |
| 2023 | 20,986 | 267,327 | 57.0% | 12,738 |
| 2022 | 23,861 | 351,670 | 64.8% | 14,738 |
| 2021 | 22,826 | 265,020 | 62.0% | 11,610 |
| 2020 | 25,552 | 280,881 | 69.3% | 10,993 |
| 2019 | 27,858 | 322,181 | 75.7% | 11,565 |
| 2018 | 29,625 | 356,576 | 80.5% | 12,036 |
| 2017 | 28,547 | 350,853 | 77.6% | 12,290 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.