- Bioenergy
- Operating
- 10 · 100 · 1,000 MW
Map
- Bioenergy
- Operating
Grayling Generating Station: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Grayling Generating Station
Power plant · Biomass
Key facts
Power plant · Biomassran 54% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1992
- Net generation, 2025
- 181,959 MWh
- Grid
- 46 kV to Consumers Energy Co (MISO)
- Location
- Crawford County, Michigan
- Operated by
- NorthStar Clean Energy
Operations
- Net generation, 2025
- 181,959
MWh - Fuel burned, 2025
- 2,481,520
MMBtu - Capacity factor, 2025
- 53.8
% - Heat rate, 2025
- 13,638
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 181,959 | 2,481,520 | 53.8% | 13,638 |
| 2024 | 164,587 | 2,291,577 | 48.5% | 13,923 |
| 2023 | 134,124 | 2,022,650 | 39.7% | 15,080 |
| 2022 | 219,171 | 3,183,199 | 64.8% | 14,524 |
| 2021 | 203,861 | 3,073,181 | 60.3% | 15,075 |
| 2020 | 66,339 | 1,121,206 | 19.6% | 16,901 |
| 2019 | 171,210 | 2,561,972 | 50.6% | 14,964 |
| 2018 | 176,312 | 2,590,383 | 52.1% | 14,692 |
| 2017 | 160,216 | 2,500,428 | 47.4% | 15,607 |
| 2016 | 131,400 | 2,204,841 | 38.8% | 16,780 |
| 2015 | 116,340 | 1,825,824 | 34.4% | 15,694 |
| 2014 | 207,775 | 3,187,442 | 61.5% | 15,341 |
| 2013 | 176,855 | 2,550,565 | 52.3% | 14,422 |
| 2012 | 164,338 | 2,448,951 | 48.5% | 14,902 |
| 2011 | 224,135 | 3,091,901 | 66.3% | 13,795 |
| 2010 | 216,788 | 2,903,218 | 64.1% | 13,392 |
| 2009 | 190,207 | 2,928,246 | 56.2% | 15,395 |
| 2008 | 233,411 | 3,229,743 | 68.8% | 13,837 |
| 2007 | 245,997 | 3,510,613 | 72.8% | 14,271 |
| 2006 | 242,017 | 3,303,664 | 71.6% | 13,650 |
| 2005 | 253,529 | 3,679,786 | 75.0% | 14,514 |
| 2004 | 278,654 | 4,067,542 | 82.2% | 14,597 |
| 2003 | 233,112 | 3,302,417 | 68.9% | 14,167 |
| 2002 | 198,481 | 3,059,053 | 58.7% | 15,412 |
| 2001 | 241,998 | 3,567,813 | 71.6% | 14,743 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)