Greenleaf 1
Power plant · Gas, combustion turbine
Key facts
Power plant · Gas, combustion turbineran 0% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2022
- Net generation, 2025
- 2,626 MWh
- Grid
- 115 kV to Pacific Gas & Electric Co (CISO)
- Location
- Sutter County, California
- Operated by
- Calpine Greenleaf Holding, Inc.
Operations
- Net generation, 2025
- 2,626
MWh - Fuel burned, 2025
- 14,062
MMBtu - Capacity factor, 2025
- 0.4
% - Heat rate, 2025
- 5,355
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 2,626 | 14,062 | 0.4% | 5,355 |
| 2024 | 4,069 | 41,960 | 0.7% | 10,312 |
| 2023 | 2,568 | 27,081 | 0.4% | 10,546 |
| 2022 (5 of 12 months) | 1,672 | 17,836 | — | 10,668 |
| 2021 | 1,008 | 10,587 | 0.2% | 10,503 |
| 2019 | 8,811 | 79,592 | 1.4% | 9,033 |
| 2018 | 67,014 | 596,062 | 11.0% | 8,895 |
| 2017 | 25,615 | 228,987 | 4.2% | 8,940 |
| 2016 | 46,621 | 345,054 | 7.6% | 7,401 |
| 2015 | 33,146 | 307,302 | 5.4% | 9,271 |
| 2014 | 15,854 | 163,727 | 2.6% | 10,327 |
| 2013 | 21,634 | 1,717,528 | 3.5% | — |
| 2012 | 60,273 | 510,853 | 9.8% | 8,476 |
| 2011 | 209,155 | 1,744,338 | 34.2% | 8,340 |
| 2010 | 245,816 | 2,035,870 | 40.2% | 8,282 |
| 2009 | 223,472 | 1,845,900 | 36.5% | 8,260 |
| 2008 | 231,477 | 1,920,065 | 37.8% | 8,295 |
| 2007 | 286,730 | 2,406,309 | 46.9% | 8,392 |
| 2006 | 289,510 | 2,363,776 | 47.3% | 8,165 |
| 2005 | 264,296 | 2,425,483 | 43.2% | 9,177 |
| 2004 | 328,006 | 2,921,989 | 53.5% | 8,908 |
| 2003 | 384,532 | 3,085,794 | 62.9% | 8,025 |
| 2002 | 373,075 | 2,989,146 | 61.0% | 8,012 |
| 2001 | 399,386 | 3,112,120 | 65.3% | 7,792 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.