- Wind & solar
- Operating
- 10 · 100 · 1,000 MW
Map
- Wind & solar
- Operating
Hancock County Wind Energy Center: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Hancock County Wind Energy Center
Power plant · Wind
Key facts
Power plant · Windran 30% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2002
- Net generation, 2025
- 255,466 MWh
- Grid
- 230 kV to Interstate Power and Light Co (MISO)
- Location
- Hancock County, Iowa
- Operated by
- FPL Energy Hancock County Wind, LLCSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 255,466
MWh - Fuel burned, 2025
- 871,650
MMBtu - Capacity factor, 2025
- 29.8
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 155,838 | 531,719 | — | — |
| 2025 | 255,466 | 871,650 | 29.8% | — |
| 2024 | 268,412 | 915,821 | 31.2% | — |
| 2023 | 256,785 | 876,152 | 29.9% | — |
| 2022 | 312,194 | 1,065,206 | 36.4% | — |
| 2021 | 240,914 | 2,130,642 | 28.1% | — |
| 2020 | 247,213 | 2,167,317 | 28.7% | — |
| 2019 | 200,189 | 1,782,684 | 23.3% | — |
| 2018 | 232,448 | 2,116,208 | 27.1% | — |
| 2017 | 253,284 | 2,333,506 | 29.5% | — |
| 2016 | 246,354 | 2,274,340 | 28.6% | — |
| 2015 | 256,567 | 2,390,947 | 29.9% | — |
| 2014 | 269,038 | 2,558,550 | 31.3% | — |
| 2013 | 280,968 | 2,680,715 | 32.7% | — |
| 2012 | 255,856 | 2,434,726 | 29.7% | — |
| 2011 | 241,604 | 2,347,425 | 28.1% | — |
| 2010 | 239,020 | 2,331,882 | 27.8% | — |
| 2009 | 222,989 | 2,176,375 | 26.0% | — |
| 2008 | 238,634 | 2,351,500 | 27.7% | — |
| 2007 | 255,055 | 2,520,965 | 29.7% | — |
| 2006 | 256,935 | 2,548,537 | 29.9% | — |
| 2005 | 243,611 | 2,435,866 | 28.4% | — |
| 2004 | 270,203 | 2,707,974 | 31.4% | — |
| 2003 | 260,456 | 2,667,332 | 30.3% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)