Hastings City Hydroelectric
Power plant · Hydro
Key facts
Power plant · Hydroran 36% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1992
- Net generation, 2025
- 13,917 MWh
- Grid
- 12 kV to Northern States Power Co - Minnesota (MISO)
- Location
- Dakota County, Minnesota
- Operated by
- Hastings Lock & DamSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 13,917
MWh - Fuel burned, 2025
- 47,710
MMBtu - Capacity factor, 2025
- 36.1
% - Heat rate, 2025
- Not stated
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 13,917 | 47,710 | 36.1% | — |
| 2024 | 13,251 | 45,254 | 34.3% | — |
| 2023 | 22,398 | 76,435 | 58.1% | — |
| 2022 | 22,612 | 77,151 | 58.7% | — |
| 2021 | 24,667 | 218,156 | 64.0% | — |
| 2020 | 16,228 | 142,270 | 42.0% | — |
| 2019 | 12,744 | 113,485 | 33.1% | — |
| 2018 | 13,105 | 119,308 | 34.0% | — |
| 2017 | 17,897 | 164,886 | 46.4% | — |
| 2016 | 18,422 | 170,071 | 47.7% | — |
| 2015 | 27,684 | 257,988 | 71.8% | — |
| 2014 | 18,178 | 172,872 | 47.2% | — |
| 2013 | 18,717 | 178,577 | 48.6% | — |
| 2012 | 21,261 | 202,319 | 55.0% | — |
| 2011 | 17,812 | 173,061 | 46.2% | — |
| 2010 | 17,425 | 169,998 | 45.2% | — |
| 2009 | 26,379 | 257,459 | 68.4% | — |
| 2008 | 22,219 | 218,947 | 57.5% | — |
| 2007 | 25,007 | 247,168 | 64.9% | — |
| 2006 | 24,182 | 239,860 | 62.7% | — |
| 2005 | 24,398 | 243,956 | 63.3% | — |
| 2004 | 19,497 | 195,399 | 50.4% | — |
| 2003 | 20,089 | 205,732 | 52.1% | — |
| 2002 | 3,535 | 35,962 | 9.2% | — |
| 2001 | 7,814 | 80,742 | 20.3% | — |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.