Hunterstown Power Plant
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 77% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2003
- Net generation, 2025
- 6,086,583 MWh
- Grid
- 500 kV to Metropolitan Edison Co (PJM)
- Location
- Adams County, Pennsylvania
- Operated by
- Hunterstown Generation, LLC
Operations
- Net generation, 2025
- 6,086,583
MWh - Fuel burned, 2025
- 43,012,096
MMBtu - Capacity factor, 2025
- 77.4
% - Heat rate, 2025
- 7,067
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 3,813,940 | 27,021,204 | — | 7,085 |
| 2025 | 6,086,583 | 43,012,096 | 77.4% | 7,067 |
| 2024 | 5,465,138 | 39,004,441 | 69.3% | 7,137 |
| 2023 | 5,057,551 | 36,087,934 | 64.3% | 7,136 |
| 2022 | 5,914,124 | 41,842,972 | 75.2% | 7,075 |
| 2021 | 5,707,527 | 40,387,474 | 72.6% | 7,076 |
| 2020 | 6,570,656 | 46,596,239 | 83.3% | 7,092 |
| 2019 | 5,863,953 | 41,362,305 | 74.5% | 7,054 |
| 2018 | 5,311,726 | 37,636,161 | 67.5% | 7,086 |
| 2017 | 5,049,276 | 36,015,551 | 64.2% | 7,133 |
| 2016 | 4,577,462 | 32,381,955 | 58.0% | 7,074 |
| 2015 | 5,095,053 | 35,791,488 | 64.8% | 7,025 |
| 2014 | 3,834,528 | 26,845,300 | 48.8% | 7,001 |
| 2013 | 4,344,588 | 30,823,528 | 55.2% | 7,095 |
| 2012 | 4,326,384 | 30,857,556 | 54.9% | 7,132 |
| 2011 | 4,194,611 | 30,092,912 | 53.3% | 7,174 |
| 2010 | 2,266,895 | 16,695,755 | 28.8% | 7,365 |
| 2009 | 1,900,021 | 13,925,385 | 24.1% | 7,329 |
| 2008 | 1,084,694 | 8,141,033 | 13.8% | 7,505 |
| 2007 | 1,190,623 | 8,800,670 | 15.1% | 7,392 |
| 2006 | 725,691 | 5,496,757 | 9.2% | 7,574 |
| 2005 | 714,682 | 5,569,561 | 9.1% | 7,793 |
| 2004 | 283,944 | 2,197,089 | 3.6% | 7,738 |
| 2003 (6 of 12 months) | 21,139 | 246,995 | — | 11,684 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.