- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Indeck Oswego Energy Center: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Indeck Oswego Energy Center
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 23% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 1990
- Net generation, 2025
- 117,766 MWh
- Grid
- 115 kV to Niagara Mohawk Power Corp. (NYIS)
- Location
- Oswego County, New York
- Operated by
- Indeck-Oswego Ltd Partnership
Operations
- Net generation, 2025
- 117,766
MWh - Fuel burned, 2025
- 1,091,955
MMBtu - Capacity factor, 2025
- 23.4
% - Heat rate, 2025
- 9,272
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2025 | 117,766 | 1,091,955 | 23.4% | 9,272 |
| 2024 | 49,822 | 463,371 | 9.9% | 9,300 |
| 2023 | 36,271 | 348,276 | 7.2% | 9,602 |
| 2022 | 13,018 | 123,302 | 2.6% | 9,472 |
| 2021 | 23,659 | 224,257 | 4.7% | 9,479 |
| 2020 | 19,668 | 187,541 | 3.9% | 9,535 |
| 2019 | 24,724 | 240,628 | 4.9% | 9,733 |
| 2018 | 68,385 | 641,937 | 13.6% | 9,387 |
| 2017 | 55,818 | 520,481 | 11.1% | 9,325 |
| 2016 | 52,785 | 479,152 | 10.5% | 9,077 |
| 2015 | 88,781 | 837,299 | 17.7% | 9,431 |
| 2014 | 65,294 | 604,416 | 13.0% | 9,257 |
| 2013 | 46,844 | 429,621 | 9.3% | 9,171 |
| 2012 | 25,266 | 235,639 | 5.0% | 9,326 |
| 2011 | 11,423 | 108,863 | 2.3% | 9,530 |
| 2010 | 9,144 | 83,371 | 1.8% | 9,118 |
| 2009 | 3,780 | 38,342 | 0.8% | 10,143 |
| 2008 | 11,305 | 108,462 | 2.2% | 9,594 |
| 2007 | 25,092 | 239,418 | 5.0% | 9,542 |
| 2006 | 9,119 | 89,765 | 1.8% | 9,844 |
| 2005 | 12,571 | 126,453 | 2.5% | 10,059 |
| 2004 | 11,914 | 115,765 | 2.4% | 9,717 |
| 2003 | 112,501 | 947,067 | 22.4% | 8,418 |
| 2002 | 96,503 | 902,551 | 19.2% | 9,353 |
| 2001 | 28,311 | 278,589 | 5.6% | 9,840 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)