- Combustion
- Operating
- 10 · 100 · 1,000 MW
Map
- Combustion
- Operating
Jack County: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Jack County
Power plant · Gas, combined cycle
Key facts
Power plant · Gas, combined cycleran 56% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2006
- Net generation, 2025
- 6,251,601 MWh
- Grid
- 345 kV, 138 kV to Oncor Electric Delivery Company LLC (ERCO)
- Location
- Wise County, Texas
- Operated by
- Jack County Power, LLC
Operations
- Net generation, 2025
- 6,251,601
MWh - Fuel burned, 2025
- 45,866,464
MMBtu - Capacity factor, 2025
- 55.8
% - Heat rate, 2025
- 7,337
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 2,093,644 | 15,569,649 | — | 7,437 |
| 2025 | 6,251,601 | 45,866,464 | 55.8% | 7,337 |
| 2024 | 6,761,183 | 49,144,812 | 60.1% | 7,269 |
| 2023 | 6,252,133 | 45,180,811 | 55.8% | 7,226 |
| 2022 | 5,486,223 | 40,102,408 | 48.9% | 7,310 |
| 2021 | 3,657,619 | 26,947,484 | 32.6% | 7,368 |
| 2020 | 3,305,053 | 24,575,631 | 29.4% | 7,436 |
| 2019 | 4,066,724 | 30,070,333 | 36.3% | 7,394 |
| 2018 | 3,651,675 | 27,120,485 | 32.6% | 7,427 |
| 2017 | 3,244,875 | 24,136,746 | 28.9% | 7,438 |
| 2016 | 5,347,073 | 39,157,551 | 47.6% | 7,323 |
| 2015 | 6,187,538 | 44,805,429 | 55.2% | 7,241 |
| 2014 | 6,240,763 | 44,844,932 | 55.7% | 7,186 |
| 2013 | 5,432,917 | 38,743,688 | 48.4% | 7,131 |
| 2012 | 5,521,747 | 39,337,909 | 49.1% | 7,124 |
| 2011 | 3,966,698 | 28,551,661 | 35.4% | 7,198 |
| 2010 | 3,128,138 | 22,691,107 | 27.9% | 7,254 |
| 2009 | 3,296,975 | 23,665,933 | 29.4% | 7,178 |
| 2008 | 3,125,963 | 22,320,707 | 27.8% | 7,140 |
| 2007 | 3,566,335 | 25,636,518 | 31.8% | 7,188 |
| 2006 (11 of 12 months) | 3,063,108 | 21,922,775 | — | 7,157 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.
Sources
3 sourcesSources
- EIA-860M
- GEMGlobal Integrated Power Tracker, Global Energy Monitor, September 2026 release (https://globalenergymonitor.org/projects/global-integrated-power-tracker), CC BY 4.0. Modified by Inframation: TransitionZero-sourced rows removed; statuses and technologies mapped to Inframation's vocabulary; figures aggregated. Copyright © Global Energy Monitor. Global Integrated Power Tracker, September 2026 release. Distributed under a Creative Commons Attribution 4.0 International License.
- EIASource: U.S. Energy Information Administration, Electricity bulk data (Form EIA-923 monthly plant series)