- Unspecified fuel
- Operating
- 10 · 100 · 1,000 MW
Map
- Unspecified fuel
- Operating
Kapaia Power Station: location. Basemap: Protomaps, © OpenStreetMap contributors, ODbL.
Kapaia Power Station
Power plant · Other
Key facts
Power plant · Otherran 56% of 2025 Operating- Capacity
- Capacity: sourceEIA-860M · Open licenseMW
- Commissioned
- 2002
- Net generation, 2025
- 190,113 MWh
- Grid
- 57 kV to Kauai Island Utility Cooperative
- Location
- Kauai County, Hawaii
- Operated by
- Kauai Island Utility CooperativeSourceEIA-860M Preliminary Monthly Electric Generator Inventory
Operations
- Net generation, 2025
- 190,113
MWh - Fuel burned, 2025
- 1,764,676
MMBtu - Capacity factor, 2025
- 55.5
% - Heat rate, 2025
- 9,282
Btu/kWh
| Year | Net generation (MWh) | Fuel burned (MMBtu) | Capacity factor | Heat rate (Btu/kWh) |
|---|---|---|---|---|
| 2026 (8 of 12 months) | 119,499 | 1,108,332 | — | 9,275 |
| 2025 | 190,113 | 1,764,676 | 55.5% | 9,282 |
| 2024 | 190,798 | 1,668,145 | 55.5% | 8,743 |
| 2023 | 178,995 | 1,674,812 | 52.3% | 9,357 |
| 2022 | 168,632 | 1,590,402 | 49.2% | 9,431 |
| 2021 | 146,477 | 1,372,011 | 42.8% | 9,367 |
| 2020 | 139,395 | 1,289,236 | 40.6% | 9,249 |
| 2019 | 174,281 | 1,591,690 | 50.9% | 9,133 |
| 2018 | 192,263 | 1,725,765 | 56.1% | 8,976 |
| 2017 | 185,155 | 1,647,983 | 54.1% | 8,901 |
| 2016 | 182,128 | 1,651,953 | 53.0% | 9,070 |
| 2015 | 179,989 | 1,769,806 | 52.5% | 9,833 |
| 2014 | 210,818 | 1,844,732 | 61.6% | 8,750 |
| 2013 | 206,287 | 1,805,078 | 60.2% | 8,750 |
| 2012 | 220,526 | 1,917,975 | 64.2% | 8,697 |
| 2011 | 211,971 | 1,837,484 | 61.9% | 8,669 |
| 2010 | 219,139 | 1,922,064 | 64.0% | 8,771 |
| 2009 | 215,583 | 1,897,800 | 62.9% | 8,803 |
| 2008 | 216,262 | 1,902,607 | 63.0% | 8,798 |
| 2007 | 220,310 | 1,909,185 | 64.3% | 8,666 |
| 2006 | 217,056 | 1,854,961 | 63.4% | 8,546 |
| 2005 | 211,678 | 1,802,517 | 61.8% | 8,515 |
| 2004 | 195,708 | 1,671,931 | 57.0% | 8,543 |
How these are worked out
Net generation and fuel burned are the monthly figures EIA publishes in its bulk electricity file, from the plant's Form 923 reports; a year is the sum of its months. Capacity factor is a full year's net generation over today's nameplate capacity times the hours in that year (8,784 in a leap year), so a plant uprated or partly retired since reads against its current size; heat rate is fuel burned over net generation, for plants that burn fuel. A year with fewer than twelve months stated has no capacity factor, and a value outside the plausible range is left blank rather than shown. By month, the charts apply the same rules to each month's own hours and fuel.